Br J OphthalmolJanuary 202015 citations

Hybrid Descemet Membrane Endothelial Keratoplasty (H-DMEK): results of a donor insertion pull-through technique using donor stroma as carrier.

Woo Jyh Haur, Htoon Hla Myint, Tan Donald


AI Summary

Hybrid DMEK using a pull-through technique with stromal carrier shows promise for endothelial transplantation, especially in complex eyes, with good visual outcomes and manageable complications.

Abstract

Aim

To evaluate the outcomes and complications of hybrid Descemet membrane endothelial keratoplasty (H-DMEK) using a Descemet stripping automated endothelial keratoplasty (DSAEK) pull-through donor inserter and donor stroma as carrier.

Methods

This was a retrospective interventional case series of eyes with bullous keratopathy (BK) and Fuchs endothelial corneal dystrophy (FECD), which underwent H-DMEK, performed using a bimanual pull-through technique using DSAEK-prepared donor stroma as carrier and the EndoGlide Ultrathin DSAEK donor insertion device. Complex cases with tube shunts, trabeculectomy, aphakia, aniridia, previous vitrectomy, keratoplasty or combined with intraocular lens exchange, were also included. The outcome measures were intraoperative and postoperative complications, best corrected visual acuity (BCVA) and endothelial cell loss after surgery.

Results

Of the 85 eyes from 79 patients, 43.5% (n=37) had BK, 28.2% (n=24) had FECD while 24.7% (n=21) had failed grafts. DMEK was performed in 37 complex eyes (43.5%). Four eyes (4.7%) required rebubbling for graft detachment and two cases of graft failure were observed. A BCVA of 20/25 or better was attained in 44.7% and 57.1% of eyes without pre-existing ocular pathology at 6 and 12 months, respectively. The overall endothelial cell loss was 32.2%±20.5% at 6 months, which improved from 37.2%±20.9% to 24.2%±17.5%, comparing the first 40 and last 45 cases (p=0.012).

Conclusion

Hybrid DMEK offers a controlled 'pull-through' technique of donor insertion in the 'endothelium-in' configuration, which may be useful especially in complicated eyes. More studies are needed to confirm the long-term endothelial cell loss and graft survival associated with this technique.


MeSH Terms

AgedCorneal DiseasesCorneal Endothelial Cell LossCorneal StromaDescemet MembraneDescemet Stripping Endothelial KeratoplastyFemaleFuchs' Endothelial DystrophyGraft SurvivalHumansIntraoperative ComplicationsMaleMiddle AgedPostoperative ComplicationsReoperationRetrospective StudiesTissue DonorsTreatment OutcomeVisual Acuity

Key Concepts5

In a retrospective interventional case series of 85 eyes from 79 patients undergoing hybrid Descemet membrane endothelial keratoplasty (H-DMEK), 4.7% (n=4) required rebubbling for graft detachment and two cases of graft failure were observed.

PrognosisCase seriesRetrospective interventional case seriesn=85 eyes from 79 patientsCh17

A best corrected visual acuity (BCVA) of 20/25 or better was attained in 44.7% of eyes without pre-existing ocular pathology at 6 months and 57.1% at 12 months after hybrid Descemet membrane endothelial keratoplasty (H-DMEK).

PrognosisCase seriesRetrospective interventional case seriesn=85 eyes from 79 patientsCh17

The overall endothelial cell loss after hybrid Descemet membrane endothelial keratoplasty (H-DMEK) was 32.2%±20.5% at 6 months, which improved from 37.2%±20.9% in the first 40 cases to 24.2%±17.5% in the last 45 cases (p=0.012).

PrognosisCase seriesRetrospective interventional case seriesn=85 eyes from 79 patientsCh17

Hybrid Descemet membrane endothelial keratoplasty (H-DMEK) using a Descemet stripping automated endothelial keratoplasty (DSAEK) pull-through donor inserter and donor stroma as carrier was evaluated in a retrospective interventional case series of 85 eyes from 79 patients with bullous keratopathy (BK) and Fuchs endothelial corneal dystrophy (FECD).

MethodologyCase seriesRetrospective interventional case seriesn=85 eyes from 79 patientsCh17

Hybrid Descemet membrane endothelial keratoplasty (H-DMEK) offers a controlled 'pull-through' technique of donor insertion in the 'endothelium-in' configuration, which may be useful especially in complicated eyes, based on a retrospective interventional case series of 85 eyes from 79 patients.

TreatmentCase seriesRetrospective interventional case seriesn=85 eyes from 79 patientsCh17

Is this article assigned to the wrong chapter(s)? Let us know.