Exploring iridotrabecular contact index and related factors in primary angle closure disease: a swept-source anterior segment OCT study.
Jeong Yoon, Park Ki Ho, Jeoung Jin Wook
AI Summary
This study found a significant link between lens vault and iridotrabecular contact (ITC) in primary angle closure. However, lens vault didn't improve diagnostic accuracy for ITC, suggesting other angle parameters are more crucial for comprehensive PACD evaluation.
Abstract
Background/aims: This study evaluates the relationship between the iridotrabecular contact (ITC) index and various anterior segment parameters, with a particular focus on lens-related parameters, given their clinical relevance in primary angle closure disease (PACD).
Methods
A retrospective analysis was conducted on consecutive patients with PACD who underwent swept-source anterior segment optical coherence tomography (AS-OCT). All AS-OCT images were manually reviewed. Relative lens vault greater than one-third was defined as 'high vault'." The ability to detect an ITC index ≥50% was assessed using area under the receiver operating characteristic curve (AUROC). Decision tree analysis identified factors influencing the ITC index.
Results
A total of 376 patients were initially identified, and after applying exclusion criteria, 119 eyes of 119 PACD patients were included in the final analysis. The mean ITC index was 50.2%±30.5%, with a mean relative lens vault of 0.31±0.10. High vault was significantly associated with higher ITC index (p<0.001), and a positive correlation was observed (r=0.451, p<0.001). The angle recess area at 500 µm (ARA 500) parameter had the highest AUROC (0.983) for detecting ITC index ≥50%. Decision tree analysis identified trabecular iris space area at 500 µm and ARA 500 as key factors, but adding relative lens vault did not improve differentiation.
Conclusions
A significant correlation exists between relative lens vault and the ITC index in PACD. However, lens vault does not enhance the diagnostic accuracy of angle parameters for identifying the ITC index. Comprehensive evaluation of PACD should include parameters beyond lens measurements.
Key Concepts5
In a retrospective analysis of 119 eyes from 119 primary angle closure disease (PACD) patients, a high relative lens vault (greater than one-third) was significantly associated with a higher iridotrabecular contact (ITC) index (p<0.001), and a positive correlation was observed (r=0.451, p<0.001).
In a retrospective analysis of 119 eyes from 119 primary angle closure disease (PACD) patients, the angle recess area at 500 µm (ARA 500) parameter had the highest area under the receiver operating characteristic curve (AUROC) (0.983) for detecting an iridotrabecular contact (ITC) index ≥50%.
Decision tree analysis in a retrospective study of 119 eyes from 119 primary angle closure disease (PACD) patients identified trabecular iris space area at 500 µm and angle recess area at 500 µm (ARA 500) as key factors influencing the iridotrabecular contact (ITC) index, but adding relative lens vault did not improve differentiation.
In a retrospective analysis of 119 eyes from 119 primary angle closure disease (PACD) patients, a significant correlation exists between relative lens vault and the iridotrabecular contact (ITC) index, however, lens vault does not enhance the diagnostic accuracy of angle parameters for identifying the ITC index.
A retrospective analysis of 119 eyes from 119 primary angle closure disease (PACD) patients found that the mean iridotrabecular contact (ITC) index was 50.2%±30.5%, with a mean relative lens vault of 0.31±0.10.
Related Articles5
Short-Term Ocular Biometric Changes as Predictors of Long-Term Angle Closure Progression.
Cohort StudyAcute Angle Closure Incidence in a Large Countywide Safety Net Teleretinal Screening Program.
Cohort StudyDeep learning model for extensive smartphone-based diagnosis and triage of cataracts and multiple corneal diseases.
Observational StudyAqueous Angiography-Guided Bent Ab Interno Needle Goniectomy in High Versus Low Aqueous Humor Outflow Regions in Primary Open Angle Glaucoma: A Pilot Randomized Controlled Trial.
Randomized Controlled TrialSafety Assessment of Aqueous Humor Liquid Biopsy in Retinoblastoma: A Multicenter Study of 1203 Procedures.
Observational StudyIs this article assigned to the wrong chapter(s)? Let us know.