Optimal number of angle images for calculating anterior angle volume and iris volume measurements.
Lauren S Blieden, Alice Z Chuang, Laura A Baker, Nicholas P Bell, Timothy S Fuller, Kimberly A Mankiewicz, Robert M Feldman
Summary
It is possible to determine TICV and IV parameters reliably in narrow angles without evaluating all 128 meridians obtained with SSFD-ASOCT.
Abstract
PURPOSE
We determined the optimal number of angle images required to obtain reliable measurements of trabecular-iris circumferential volume (TICV) and iris volume (IV) using swept-source Fourier domain anterior segment optical coherence tomography (SSFD-ASOCT) scans in narrow angle eyes.
METHODS
Scleral spur landmarks (SSL) were manually identified on ASOCT angle images from 128 meridians from each of 24 eyes with chronic primary angle closure (PAC) spectrum of disease. The anterior and posterior corneal curves, and the anterior and posterior iris surfaces were identified automatically by the anterior chamber analysis and interpretation (ACAI) software, then manually examined and edited by the reader if required. Trabecular-iris circumferential volume at 750 μm from SSL (TICV750) and IV were subsequently calculated using varying numbers of angle images. Threshold error was determined to be less than the lower 95% confidence limit of mean absolute percent error (MAPE) of the change in TICV or IV resulting from laser peripheral iridotomy, which would be 17% for TICV and 5% for IV, based on previous studies. The optimal number of angle images was the smallest number of images where MAPE was less than this threshold for TICV and IV.
RESULTS
A total of 32 equally-spaced angle images (16 meridians) was required to estimate TICV750 and 16 angle images (8 meridians) to estimate IV. Both were within 4.6% and 1.6% of MAPE, respectively.
CONCLUSIONS
It is possible to determine TICV and IV parameters reliably in narrow angles without evaluating all 128 meridians obtained with SSFD-ASOCT.
More by Lauren S Blieden
View full profile →Genetic Architecture of Primary Open-Angle Glaucoma in Individuals of African Descent: The African Descent and Glaucoma Evaluation Study III.
The African Descent and Glaucoma Evaluation Study (ADAGES) III: Contribution of Genotype to Glaucoma Phenotype in African Americans: Study Design and Baseline Data.
Long-term Outcome of Argon Laser Peripheral Iridoplasty in the Management of Plateau Iris Syndrome Eyes.
Top Research in OCT & Imaging
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Deep learning in ophthalmology: The technical and clinical considerations.
Anterior segment optical coherence tomography.
Discussion
Comments and discussion will appear here in a future update.