Diagnostic Ability of Retinal Vessel Diameter Measurements in Open-Angle Glaucoma.
Eunjoo Yoo, Chungkwon Yoo, Bo-Ram Lee, Tae-Eun Lee, Yong Yeon Kim
Summary
The diagnostic ability of CRAE for detecting OAG was good, which was not much worse than that of average RNFL thickness. This finding suggests the potential usefulness of RVD for glaucoma detection.
Abstract
PURPOSE
To determine the diagnostic ability of retinal vessel diameter (RVD) measurements and the factors related to retinal vascular diameters in patients with open-angle glaucoma (OAG).
METHODS
This retrospective observational study included 145 patients with OAG (63 with high-tension and 82 with low-tension glaucoma) and 60 healthy controls. The central retinal arteriolar equivalent (CRAE) and central retinal venular equivalent (CRVE) were measured using the IVAN software version 1.3. Receiver operating characteristic (ROC) curves were obtained for the average retinal nerve fiber layer (RNFL) thickness and RVD indices including CRAE, CRVE, and CRAE/CRVE ratio. Areas under the ROC curves (AUCs), 95% confidence intervals (CIs), and sensitivities at a fixed specificity (>90% and >80%) were calculated. Factors related to CRAE were analyzed by simple and multiple linear regression analyses.
RESULTS
Among the RVD indices, the CRAE had the largest AUC for discriminating glaucomatous changes between eyes with glaucoma and those without (0.803; 95% CI, 0.742-0.855). The AUC of CRAE did not significantly differ from that of average RNFL thickness (P = 0.134). However, CRAE showed lower sensitivity than average RNFL thickness at a specificity greater than 90%. Factors significantly associated with CRAE in both simple and multiple linear regression analyses were age, spherical equivalent, average RNFL thickness, presence of diabetes mellitus, and a glaucoma diagnosis (all P ≤ 0.05).
CONCLUSIONS
The diagnostic ability of CRAE for detecting OAG was good, which was not much worse than that of average RNFL thickness. This finding suggests the potential usefulness of RVD for glaucoma detection.
More by Eunjoo Yoo
View full profile →Comparison of Retinal Vessel Diameter Between Open-Angle Glaucoma Patients With Initial Parafoveal Scotoma and Peripheral Nasal Step.
Retinal vessel diameter in bilateral glaucoma suspects: comparison between the eye converted to glaucoma and the contralateral non-converted eye.
Long-term Surgical Outcomes of 180-Degree Suture Trabeculotomy in Korean Patients With Primary Congenital Glaucoma.
Top Research in Diagnosis & Screening
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Dry eye disease and oxidative stress.
Central Corneal Thickness in the Ocular Hypertension Treatment Study (OHTS).
Discussion
Comments and discussion will appear here in a future update.