Structure-Function Relationship in Glaucoma Patients With Parafoveal Versus Peripheral Nasal Scotoma.
Summary
In glaucoma with peripheral scotoma, the RNFL thickness was associated significantly with the corresponding VF loss in SAP, FDT, and SWAP.
Abstract
PURPOSE
We evaluated whether the structure-function relationship in glaucoma patients with parafoveal scotoma or peripheral scotoma differs with the use of frequency doubling technology (FDT) or short-wavelength automated perimetry (SWAP) compared to standard automated perimetry (SAP).
METHODS
Glaucoma patients with isolated parafoveal scotoma (PFS) within the central 10° of fixation in 1 hemifield and those with an isolated peripheral nasal step (PNS) within the nasal periphery outside 10° of fixation in one hemifield were studied. Peripapillary retinal nerve fiber layer (RNFL) thickness was measured using spectral-domain optical coherence tomography. The topographic relationships between structure and function were investigated.
RESULTS
In the PNS group, superotemporal (r(2) = 0.300, P = 0.001) and inferotemporal (r(2) = 0.302, P = 0.001) RNFL thickness showed significant correlations with the corresponding visual field (VF) sensitivity using linear regression model in SAP. In the PFS group, temporal RNFL thickness was not correlated with nasal mean sensitivity (MS) on SAP (r(2) = 0.103, P = 0.065). Using FDT, however, the temporal RNFL thickness was correlated with nasal MS in the PFS group (r(2) = 0.277, P = 0.001). Using SWAP, the temporal RNFL thickness was not significantly associated with regional VF sensitivity in the PFS group (r(2) = 0.052, P = 0.192).
CONCLUSIONS
In glaucoma with peripheral scotoma, the RNFL thickness was associated significantly with the corresponding VF loss in SAP, FDT, and SWAP. In eyes with PFS, however, the topographic structure-function relationships were not distinct with SAP or SWAP. Frequency doubling technology performed well in terms of structure-function correlation in glaucoma with PFS.
More by Kyoung In Jung
View full profile →Pattern Electroretinograms in Preperimetric and Perimetric Glaucoma.
Risk Factors for Choroidal Detachment After Ahmed Valve Implantation in Glaucoma Patients.
Impact of Posterior Sclera on Glaucoma Progression in Treated Myopic Normal-Tension Glaucoma Using Reconstructed Optical Coherence Tomographic Images.
Top Research in Visual Field
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Improving our understanding, and detection, of glaucomatous damage: An approach based upon optical coherence tomography (OCT).
Discussion
Comments and discussion will appear here in a future update.