Binocular Measures of Visual Acuity and Visual Field versus Binocular Approximations.
Summary
We found limited benefit in binocular testing of VA in the clinical setting as a means of approximating a patient's reported visual functioning.
Abstract
PURPOSE
To assess the relationship of binocular visual function tests with binocular approximations using data from the Collaborative Initial Glaucoma Treatment Study (CIGTS).
DESIGN
Case series based on existing data from a clinical trial.
PARTICIPANTS
Six hundred seven patients with newly diagnosed open-angle glaucoma from the CIGTS.
METHODS
Monocular visual field (VF) and visual acuity (VA) tests were performed at baseline and every 6 months thereafter. Binocular tests of visual function (Esterman VF score, binocular VA) were added to the CIGTS protocol 3 years into the study. The binocular approximations of binocular visual function were better or worse eye, average eye, better or worse location, and binocular summation or pointwise binocular summation. Associations between binocular tests and binocular approximations to represent binocular visual function were assessed with Pearson's correlations (r), as was the relationship between vision-related quality of life (VR QOL; Visual Activities Questionnaire [VAQ] and the 25-item National Eye Institute Visual Function Questionnaire [NEI VFQ-25]) and binocular tests or binocular approximations of visual function.
MAIN OUTCOME MEASURES
Binocular visual function (VF and VA) and VR QOL.
RESULTS
Five hundred seventy-five patients underwent at least 1 binocular visual function test. The Esterman score was correlated significantly with all binocular approximations of VF, with r values ranging from 0.31 (worse-eye mean deviation [MD]) to 0.42 (better-eye MD; P < 0.0001 for all). Binocular VA showed stronger correlations with binocular approximations, with r values ranging from 0.65 (worse-eye VA) to 0.80 (binocular summation; P < 0.0001 for all). Correlations between the VAQ and Esterman score were stronger in 7 of 9 subscales (r = -0.14 to -0.25; P < 0.05 for all) than correlations with all 7 binocular approximations. In contrast, correlations between the VAQ and binocular VA (r = -0.07 to -0.21) were weaker in all subscales than those with better-eye, average-eye, and binocular summation of VA (r = -0.12 to -0.25), but not different from worse-eye values. These trends also were found in relevant subscales of the NEI VFQ-25.
CONCLUSIONS
We found limited benefit in binocular testing of VA in the clinical setting as a means of approximating a patient's reported visual functioning. In contrast, we found some benefit in performing binocular VF testing, because the results correlated more closely with reported functioning than binocular approximations.
More by David C Musch
View full profile →The Association between Medication Adherence and Visual Field Progression in the Collaborative Initial Glaucoma Treatment Study.
The relationship between intraocular pressure and glaucoma: An evolving concept.
Large Disparities in Receipt of Glaucoma Care between Enrollees in Medicaid and Those with Commercial Health Insurance.
Top Research in Visual Field
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Improving our understanding, and detection, of glaucomatous damage: An approach based upon optical coherence tomography (OCT).
Discussion
Comments and discussion will appear here in a future update.