Detection of Functional Change in Preperimetric and Perimetric Glaucoma Using 10-2 Matrix Perimetry.
Summary
FDT 10-2 was found to detect functional damage of the macula early in preperimetric glaucoma, and to perform better than with SAP 10-2 (size III or V) from preperimetric to perimetric glaucoma in the structure-function relationship.
Abstract
PURPOSE
To evaluate an effective functional strategy for detecting glaucomatous damage of the macula in preperimetric to perimetric glaucoma.
DESIGN
Cross-sectional study.
METHODS
Preperimetric glaucoma patients (n = 102) and perimetric glaucoma patients (n = 88) with isolated paracentral scotoma or combined paracentral scotoma were enrolled in this study. Global and sectoral mean sensitivities (MS) were evaluated using 10-2 standard automated perimetry (SAP) with a stimulus of sizes III (0.43-degree diameter) and V (1.72 degrees), and 10-2 Matrix perimetry with a stimulus of 2 degrees. Ganglion cell-inner plexiform layer (GCIPL) was measured using spectral-domain optical coherence tomography.
RESULTS
The percentage of significantly depressed visual field (VF) points <5% and <1% in the pattern deviation plot was higher with frequency doubling technology (FDT) 10-2 than with SAP 10-2 III in patients with preperimetric glaucoma (both P < .001). Using FDT 10-2 tests, the global structure-function correlation was superior to SAP 10-2 (III or V) in both preperimetric and perimetric glaucoma. Topographic structure-function relationships for each VF test were more favorable with the FDT 10-2 test. The preperimetric glaucoma patients showing VF abnormalities on FDT 10-2 or SAP 10-2 (III) showed thinner average, minimum, superior, inferior, and inferotemporal GCIPL thicknesses than in those without VF abnormalities (all P < .05).
CONCLUSIONS
FDT 10-2 was found to detect functional damage of the macula early in preperimetric glaucoma, and to perform better than with SAP 10-2 (size III or V) from preperimetric to perimetric glaucoma in the structure-function relationship. FDT 10-2 can be considered a useful tool to detect glaucomatous damage of the macula early and appropriately.
More by Kyoung In Jung
View full profile →Pattern Electroretinograms in Preperimetric and Perimetric Glaucoma.
Risk Factors for Choroidal Detachment After Ahmed Valve Implantation in Glaucoma Patients.
Impact of Posterior Sclera on Glaucoma Progression in Treated Myopic Normal-Tension Glaucoma Using Reconstructed Optical Coherence Tomographic Images.
Top Research in Visual Field
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Improving our understanding, and detection, of glaucomatous damage: An approach based upon optical coherence tomography (OCT).
Discussion
Comments and discussion will appear here in a future update.