Application of the ISNT rules on retinal nerve fibre layer thickness and neuroretinal rim area in healthy myopic eyes.
Kunliang Qiu, Geng Wang, Xuehui Lu, Riping Zhang, Lixia Sun, Mingzhi Zhang
Summary
In healthy myopic subjects, 88.4% and 37% of eyes did not comply with the ISNT rule on RNFL thickness and rim area, respectively.
Abstract
PURPOSE
We determined the applicability of inferior > superior > nasal > temporal (ISNT) rules on retinal nerve fibre layer (RNFL) thickness and rim area and evaluated the impact of various ocular factors on the performance of the ISNT rules in healthy myopic eyes.
METHODS
A total of 138 eyes from 138 healthy myopic subjects were included in this cross-sectional observational study. The peripapillary RNFL and optic disc in each eye were imaged with Cirrus HD optical coherence tomography (OCT) and Heidelberg Retina Tomograph II (HRT2), respectively. The performance of the inferior > superior (IS), inferior > superior > nasal > temporal (IST) and ISNT rules on RNFL thickness and rim area was determined and compared between low-to-moderate myopia and high myopia. The effects of ocular factors [including axial length, disc area, disc tilt, disc torsion, disc-fovea angle (DFA) and retina artery angle] on the performance of ISNT rules were evaluated with logistic regression analysis.
RESULTS
The mean axial length and refractive error were 25.57 ± 1.09 mm (range, 22.52-28.77 mm) and -5.12 ± 2.30 D [range, -9.63 to -0.50 dioptres (D)], respectively. Sixty-three per cent of the healthy eyes were compliant with the ISNT rule on rim area, while ISNT rule on RNFL thickness was followed in only 11.6% of the included eyes. For rim area, smaller disc area was significantly associated with increased compliance of the IS rule (odds ratio: 0.46, p = 0.039), IST rule (odds ratio: 0.46, p = 0.037) and ISNT rule (odds ratio: 0.44, p = 0.030). For RNFL thickness, greater DFA was significantly associated with increased compliance of the IS and IST rules (odds ratio: 1.30, p < 0.001; odds ratio: 1.19, p = 0.006, respectively).
CONCLUSION
In healthy myopic subjects, 88.4% and 37% of eyes did not comply with the ISNT rule on RNFL thickness and rim area, respectively. Due to significant low compliance in healthy eyes, the ISNT rule and its variants have limited potential utility in diagnosing glaucoma in myopic subjects.
Keywords
More by Kunliang Qiu
View full profile →Assessment of Optical Coherence Tomography Color Probability Codes in Myopic Glaucoma Eyes After Applying a Myopic Normative Database.
Re: Sugisaki et al.: Factors threatening central visual function of patients with advanced glaucoma: a prospective longitudinal observational study (Ophthalmology. 2022;129:488-497).
Influence of the Retinal Blood Vessel Topography on the Variability of the Retinal Nerve Fiber Bundle Trajectories in the Human Retina.
Top Research in Optic Nerve & Disc
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Discussion
Comments and discussion will appear here in a future update.