Precision of Optic Nerve Head and Retinal Nerve Fiber Layer Parameter Measurements by Spectral-domain Optical Coherence Tomography.
Laura M Schrems-Hoesl, Wolfgang A Schrems, Robert Laemmer, Friedrich E Kruse, Christian Y Mardin
Summary
For R&R, the COVs of measured parameters were by trend higher for glaucoma eyes compared with normal controls.
Abstract
PURPOSE
The aim of this study was to assess the repeatability and reproducibility (R&R) of Bruch membrane opening based on minimum rim width (BMO-MRW), minimum rim area (BMO-MRA) and peripapillary retinal nerve fiber layer thickness (RNFLT) with the Spectralis optical coherence tomography (Heidelberg Engineering) for normal and glaucoma subjects. Precise measurement of these parameters can support detection of structural glaucomatous damage and progression.
METHODS
This cross-sectional study included 16 healthy controls and 16 patients with glaucoma. One eye was randomly selected and included in this study. Subjects underwent 1 baseline and 3 follow-up measurements, using 3 different Spectralis optical coherence tomography devices in randomized order, each operated by a single operator. Outcome measures were global and sectorial averages of BMO-MRW and BMO-MRA, and of peripapillary RNFLT obtained from 12/14/16-degree circle scans. Coefficients of variation (COV) were calculated and a mixed-effects analysis of variance was performed to compare R&R between devices.
RESULTS
COVs of global and sectorial BMO-MRW measurement under repeatability conditions ranged from 0.51% to 1.7% (normal, 0.62% to 1.3%; glaucoma, 0.64% to 2.3%). Respective COVs under reproducibility conditions ranged from 0.89% to 1.9% (normal, 0.77% to 2.8%; glaucoma, 1.1% to 2.6%). COVs of global and sectorial RNFLT measurements under repeatability conditions ranged from 0.5% to 2.8%. Respective COVs under reproducibility conditions ranged from 1.6% to 3.5%.
CONCLUSIONS
For R&R, the COVs of measured parameters were by trend higher for glaucoma eyes compared with normal controls. The BMO-MRW measurement system has an excellent precision taking into account that major and minor corrections of segmentation have to be done by the examiner before evaluation.
More by Laura M Schrems-Hoesl
View full profile →Predictive Factors for Visual Field Conversion: Comparison of Scanning Laser Polarimetry and Optical Coherence Tomography.
Comparison of Bruch's Membrane Opening Minimum Rim Width and Peripapillary Retinal Nerve Fiber Layer Thickness in Early Glaucoma Assessment.
Confocal Laser Scanning Tomography to Predict Visual Field Conversion in Patients With Ocular Hypertension and Early Glaucoma.
Top Research in Optic Nerve & Disc
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Discussion
Comments and discussion will appear here in a future update.