Evaluation of RETICs Glaucoma Diagnostic Calculators in Preperimetric Glaucoma.
Javier Moreno-Montañés, Ana García-Nieva, Indira Aristeguieta Osio, Adriano Guarnieri, Antonio Morilla-Grasa, Marta García-Granero, Alfonso Antón
Summary
The values of both GDC were higher in the PPG group than the ocular hypertension group.
Abstract
PURPOSE
To evaluate two glaucoma diagnostic calculators (GDC) in a group of eyes with preperimetric glaucoma (PPG).
METHODS
All eyes (= 265) included in this study had ocular hypertension with normal visual fields (VFs) on repeated VF tests. PPG was defined as progression in the Guided Progression Analysis software from Cirrus-optical coherence tomography (GPA-OCT). Three PPG types were defined according to the GPA-OCT software as follows: (1) GPA-OCT with one or more red boxes in two or more columns; (2) GPA-OCT with two or more red boxes in two or more columns; and (3) GPA-OCT with two or more red boxes in two or more columns (definition 2), and in the last scan one or more red box in the RNFL average or quadrants. Nonparametric tests, areas under the receiver operating characteristic curve (AUC), and Bland-Altman tests were assessed.
RESULTS
Definitions one, two, and three were met by 44 (16.6%), 29 (10.9%), and 11 (4.2%) eyes, respectively. The GDC indices (means ± standard deviations) were, respectively, 14.49 ± 21.55% and 26.06 ± 22.50% using the combined and quantitative GDC (< 0.001) in all eyes. Both GDC showed higher glaucoma probability in the PPG group (< 0.04; combined GDC AUCs, 0.720-0.833; quantitative GDC AUCs, 0.700-0.839). GDC values were higher (< 0.01) with greater GPA progression.
CONCLUSIONS
The values of both GDC were higher in the PPG group than the ocular hypertension group. The GDC were higher when more columns in the GPA software indicated progression. Both GDC showed a similar ability to detect PPG.
TRANSLATIONAL RELEVANCE
These calculators facilitate diagnosis of PPG in ocular hypertensive eyes.
Keywords
More by Javier Moreno-Montañés
View full profile →Noninferiority of Preservative-free Versus BAK-preserved Latanoprost-timolol Fixed Combination Eye Drops in Patients With Open-angle Glaucoma or Ocular Hypertension.
Intraobserver and Interobserver Agreement of Structural and Functional Software Programs for Measuring Glaucoma Progression.
External Validation and Clinical Applicability of Two Optical Coherence Tomography-Based Risk Calculators for Detecting Glaucoma.
Top Research in OCT & Imaging
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Deep learning in ophthalmology: The technical and clinical considerations.
Anterior segment optical coherence tomography.
Discussion
Comments and discussion will appear here in a future update.