K-RIM (Corneal Rim) Angle Surgery Training Model.

Angle & Aqueous OutflowGlaucoma Surgery

Summary

Few angle surgery training models currently exist and none provide these necessary features. The model presented here aims to meet the growing demand for adequate training models required for technically advanced MIGS techniques.

Abstract

PURPOSE

To develop an angle surgery training model for training an array of microincisional glaucoma surgery (MIGS) procedures.

METHODS

We describe a method for preparing an angle surgery training model using human cadaveric corneoscleral rims. The model provides realistic tactile tissue simulation and excellent angle visualization requiring bimanual technique. Corneoscleral rims may be used multiple times and are prepared at low cost, allowing for a high volume of practice surgeries.

RESULTS

This model allows for practice in bimanual surgical training using the gonioscopy lens for visualize alongside surgical tools. The in vivo surgical conditions and limited tactile feedback are recreated using human cadaveric eyes which nonhuman models fail to provide. Our model is prepared at low cost, with relative ease and also provides appropriate positioning of Schlemm canal and for high volume of practice as the canal can be used in 90-degree segments.

CONCLUSIONS

Few angle surgery training models currently exist and none provide these necessary features. The model presented here aims to meet the growing demand for adequate training models required for technically advanced MIGS techniques.