Summary
Based on our data, the use of a contact lens statistically improved the signal strength and average NFL thickness of the SD OCT scan.
Abstract
PURPOSE
Patients with myopia are at increased risk for the development of glaucoma. The inability to correct for axial length on spectral-domain (SD) OCT translates into lower signal strength and scan reliability in patients with high axial myopia. We evaluated the effectiveness of a contact lens to increase the signal strength and to assess optic nerve dimensions and nerve fiber layer (NFL) thickness using SD OCT in patients with glaucoma or who are glaucoma suspects with high axial myopia.
DESIGN
Single-center, prospective, interventional study.
PARTICIPANTS
Patients with axial lengths of more than 25.5 mm with a diagnosis of glaucoma or glaucoma suspect.
METHODS
The optic nerve cube 200×200 scan using the Cirrus SD OCT 400 (Carl Zeiss Meditec, Inc., Dublin, CA) was carried out first without the use of a contact lens and then repeated with placement of the contact lens to correct for the spherical equivalent of the refractive error.
MAIN OUTCOME MEASURES
The primary outcome measure was the change in the average NFL thickness before and after use of the contact lens. Secondary outcome measures included the changes in cup volume, disc area, and rim area on OCT.
RESULTS
Twelve patients were recruited (20 eyes); the average axial length was 27.06 mm, and the average signal strength interval increased by 1.73 (P = 0.001). With the use of a contact lens, the average NFL thickness was significantly thicker. None of the changes in the secondary outcome measures were significant: rim area, cup volume, or disc area.
CONCLUSIONS
Based on our data, the use of a contact lens statistically improved the signal strength and average NFL thickness of the SD OCT scan. The ability to capture the perimeter of the optic disc accurately can be limited in the setting of peripapillary atrophy, which was present in all but 2 participants. Future studies with a larger number of participants and a wider range of axial myopia to discern if contact lens correction has a greater effect on the highest axial lengths are needed.
More by Meghan K Berkenstock
View full profile →Incidence and Prevalence of Scleritis Subtypes and Associated Ocular Complications in the TriNetX Database.
Incidence and Prevalence of Glaucoma, Corticosteroid Response, and Ocular Hypertension in Uveitis and its Anatomical Subtypes.
Prevalence and incidence of juvenile idiopathic arthritis-associated uveitis and medication trends in the TriNetX database.
Top Research in Optic Nerve & Disc
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Discussion
Comments and discussion will appear here in a future update.