Optical Coherence Tomography Can Be Used to Assess Glaucomatous Optic Nerve Damage in Most Eyes With High Myopia.
Zane Z Zemborain, Ravivarn Jarukasetphon, Emmanouil Tsamis, Moraes Carlos G De, Robert Ritch, Donald C Hood
Summary
For most eyes with high myopia, there is sufficient information in OCT scans to allow for accurate diagnosis of GON.
Abstract
PRECIS
It is generally assumed that optical coherence tomography (OCT) cannot be used to diagnose glaucomatous optic neuropathy (GON) in high myopes. However, this study presents evidence that there is sufficient information in OCT scans to allow for accurate diagnosis of GON in most eyes with high myopia.
PURPOSE
The purpose of this study was to test the hypothesis that glaucomatous damage can be accurately diagnosed in most high myopes via an assessment of the OCT results.
PATIENTS AND METHODS
One hundred eyes from 60 glaucoma patients or suspects, referred for OCT scans and evaluation, had corrected spherical refractive errors worse than -6 D and/or axial lengths ≥26.5 mm. An OCT specialist judged whether the eye had GON, based upon OCT circle scans of the disc and cube scans centered on the macula. A glaucoma specialist made the same judgement using all available information (eg, family history, repeat visits, intraocular pressure, 10-2 and 24-2 visual fields, OCT). A reference standard was created based upon the glaucoma specialist's classifications. In addition, the glaucoma specialist judged whether the eyes had peripapillary atrophy (PPA), epiretinal membrane (ERM), tilted disc (TD), and/or a paravascular inner retinal defect (PIRD).
RESULTS
The OCT specialist correctly identified 97 of the 100 eyes using the OCT information. In 63% of the cases, the inner circle scan alone was sufficient. For the rest, additional scans were requested. In addition, 81% of the total eyes had: PPA (79%), ERM (18%), PIRD (26%), and/or TD (48%).
CONCLUSIONS
For most eyes with high myopia, there is sufficient information in OCT scans to allow for accurate diagnosis of GON. However, the optimal use of the OCT will depend upon training to read OCT scans, which includes taking into consideration myopia related OCT artifacts and segmentation errors, as well as PPA, ERM, PIRD, and TD.
More by Zane Z Zemborain
View full profile →The OCT RNFL Probability Map and Artifacts Resembling Glaucomatous Damage.
Strategies to Improve Convolutional Neural Network Generalizability and Reference Standards for Glaucoma Detection From OCT Scans.
Reasons why OCT Global Circumpapillary Retinal Nerve Fiber Layer Thickness is a Poor Measure of Glaucomatous Progression.
Top Research in Visual Field
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Improving our understanding, and detection, of glaucomatous damage: An approach based upon optical coherence tomography (OCT).
Discussion
Comments and discussion will appear here in a future update.