Transl Vis Sci Technol
Transl Vis Sci TechnolDecember 2020Research Support, Non-U.S. Gov't

Increasing the Spatial Resolution of Visual Field Tests Without Increasing Test Duration: An Evaluation of ARREST.

Visual FieldOCT & Imaging

Summary

This study provides empirical evidence to support conclusions from previous computer simulations that ARREST can be used to increase spatial sampling in regions of interest without increasing test time.

Abstract

PURPOSE

The Australian Reduced Range Extended Spatial Test (ARREST) approach was designed to improve visual field spatial resolution while maintaining a similar test duration to clinically used testing algorithms. ARREST does not completely threshold visual field locations with sensitivity < 17 dB, and uses the presentations saved to test new locations in areas of steep gradient within the visual field. Previous assessments of ARREST's performance have used computer simulation. In this study, we cross-sectionally assessed the performance of ARREST in people with visual field loss.

METHODS

We tested 23 people with glaucoma (mean age: 71 ± 8 years) with established visual field loss. Three visual field procedures were performed using the Open Perimetry Interface: cZEST and ARREST on the Octopus 900 perimeter (Haag-Streit AG, Switzerland), and a reference standard (best available estimate [BAE]) on the Compass perimeter (CenterVue SpA, Italy). ARREST was compared against the cZEST and the BAE.

RESULTS

On average, ARREST added seven new locations (range = 0-15) to a visual field test. There was no significant difference in the number of stimulus presentations between procedures (mean = 259 ± 25 [ARREST] vs. 261 ± 25 [cZEST],= 0.78). In classifying threshold values < 17 dB, ARREST performed similarly when compared against BAE.

CONCLUSIONS

This study provides empirical evidence to support conclusions from previous computer simulations that ARREST can be used to increase spatial sampling in regions of interest without increasing test time.

TRANSLATIONAL RELEVANCE

ARREST is a new approach that augments current visual field testing procedures to provide better spatial description of visual field defects without increasing test duration.

Keywords

perimetryspatial resolutiontest durationtest gridsvisual fields

Discussion

Comments and discussion will appear here in a future update.