Comparison of Structural, Functional, Tonometric, and Visual Acuity Testing for Glaucoma: A Prospective Diagnostic Accuracy Study.
Rajesh S Kumar, B Ramgopal, Mahalakshmi V Rackenchath, V Sathi Devi A, Suria S Mannil, Sriharsha Nagaraj, Caitlin A Moe, Dionna M Wittberg, Kieran S O'Brien, Robert L Stamper, Jeremy D Keenan
Summary
OCT had moderate sensitivity and fair specificity for diagnosing moderate to advanced glaucoma and should be prioritized during an initial assessment for glaucoma.
Abstract
PURPOSE
To determine the diagnostic accuracy of potential screening tests for moderate to advanced glaucoma.
DESIGN
Prospective diagnostic test accuracy study.
PARTICIPANTS
The study enrolled a consecutive series of patients aged ≥50 years who presented to a glaucoma clinic in South India without ever having received automated visual field testing.
METHODS
All participants underwent 8 index tests: OCT of the peripapillary retinal nerve fiber layer, optic disc photography, Moorfield's Motion Displacement Test (MDT), frequency doubling technique perimetry, noncontact tonometry, pneumatonometry, presenting visual acuity, and best-corrected visual acuity. Participants also underwent stereoscopic photographs and Humphrey visual fields, which were used by 2 ophthalmologists to arrive at the reference standard diagnosis of moderate to advanced glaucoma.
MAIN OUTCOME MEASURES
Sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio.
RESULTS
A total of 217 people were enrolled; 321 eyes from 180 participants had all tests performed. Of these, 127 eyes (40%) were classified as having moderate to advanced glaucoma. Among the 8 tests, OCT best optimized sensitivity (84%, 95% confidence interval [CI], 76-90) and specificity (75%, 95% CI, 68-81). Moorfield's Motion Displacement Test was the best perimetric test, with a sensitivity of 91% (95% CI, 85-96) and specificity of 53% (95% CI, 44-61). Pressure and vision tests were not sensitive (e.g., sensitivity of 16%, 95% CI, 9-23 for noncontact tonometry and 23%, 95% CI, 15-31 for best-corrected visual acuity). Moorfield's Motion Displacement Test identified 16 of 127 eyes (13%) with glaucoma that were not captured by OCT, but also had false-positive results in 65 of 194 eyes (34%) without glaucoma that OCT correctly classified as negative.
CONCLUSIONS
OCT had moderate sensitivity and fair specificity for diagnosing moderate to advanced glaucoma and should be prioritized during an initial assessment for glaucoma.
Keywords
More by Rajesh S Kumar
View full profile →Diagnostic ability of peripapillary vessel density measurements of optical coherence tomography angiography in primary open-angle and angle-closure glaucoma.
Discriminant Function of Optical Coherence Tomography Angiography to Determine Disease Severity in Glaucoma.
The Singapore Asymptomatic Narrow Angles Laser Iridotomy Study: Five-Year Results of a Randomized Controlled Trial.
Top Research in Diagnosis & Screening
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Dry eye disease and oxidative stress.
Central Corneal Thickness in the Ocular Hypertension Treatment Study (OHTS).
Discussion
Comments and discussion will appear here in a future update.