Dynamic Alterations in Blood Flow in Glaucoma Measured with Laser Speckle Contrast Imaging.
Alfred Vinnett, Jayanth Kandukuri, Christopher Le, Kyoung-A Cho, Avigyan Sinha, Samuel Asanad, Ginger Thompson, Victoria Chen, Abhishek Rege, Osamah J Saeedi
Summary
Dynamic blood flow metrics measured with the XyCAM RI are reliable, are associated with structural and functional glaucoma metrics, and are significantly different among glaucoma, glaucoma suspect, and control participants.
Abstract
PURPOSE
To assess the repeatability of blood flow velocity index (BFVi) metrics obtained with a recently Food and Drug Administration-cleared laser speckle contrast imaging device, the XyCAM RI (Vasoptic Medical, Inc), and to characterize differences in these metrics among control, glaucoma suspect, and glaucoma participants.
DESIGN
Prospective, observational study.
PARTICIPANTS
Forty-six participants: 20 control, 16 glaucoma suspect, and 10 glaucoma participants, 1 eye per participant.
METHODS
Key dynamic BFVi metrics-mean, peak, dip, volumetric rise index (VRI), volumetric fall index (VFI), time to rise (TtR), time to fall (TtF), blow-out time (BOT), skew, and acceleration time index-were measured in the optic disc, optic disc vessels, optic disc perfusion region, and macula in 4 imaging sessions on the same day. Intrasession and intersession variability were calculated using the coefficient of variation (CV) for each metric in each region of interest (ROI). Values for each dynamic BFVi variable were compared between glaucoma, glaucoma suspect, and control participants using bivariate and multivariate analysis. Pearson correlation coefficients were used to correlate each variable in each ROI with age, intraocular pressure, cup-to-disc ratio (CDR), mean deviation, pattern standard deviation, retinal nerve fiber layer thickness, and minimum rim width.
MAIN OUTCOME MEASURES
Coefficient of variation for the intrasession and intersession variability for each dynamic BFVi metric in each ROI and differences in each metric in each ROI between each diagnostic group.
RESULTS
Intersession CV for mean, peak, dip, VRI, VFI, TtR, and TtF ranged from 3.2 ± 2.5% to 11.0 ± 3.8%. Age, CDR, OCT metrics, and visual field metrics showed significant correlations with dynamic BFVi variables. Peak, mean, dip, VRI, and VFI were significantly lower in patients with glaucoma than in control participants in all ROIs except the fovea. These metrics also were significantly lower in glaucoma patients than glaucoma suspect patients in the disc vessels.
CONCLUSIONS
Dynamic blood flow metrics measured with the XyCAM RI are reliable, are associated with structural and functional glaucoma metrics, and are significantly different among glaucoma, glaucoma suspect, and control participants. The XyCAM RI may serve as an important tool in glaucoma management in the future.
Keywords
More by Alfred Vinnett
View full profile →Top Research in Optic Nerve & Disc
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Discussion
Comments and discussion will appear here in a future update.