Gonioscopy and Angle-Based Glaucoma Surgical Training on Human Eyes in the Wet Lab.
Amar Pujari, Vaishali Rakheja, Tanuj Dada, Saurabh Verma, Shikha Gupta, Tushar Agarwal, Namrata Sharma, Jeewan S Titiyal
Summary
The residual human corneoscleral rims proved to be an important resource for teaching both the basic examination skills and those required for transitioning to advanced intraoperative gonioscopy and goniotomy skills.
Abstract
PRCIS
Human corneoscleral rims provide a low cost model and resource to enhance angle based glaucoma surgical training skills.
PURPOSE
To understand the feasibility, utility, and efficacy of a low-cost model for performing anterior chamber angle gonioscopy and micro-surgery on human corneoscleral tissues in wet lab on resident skill enhancement.
METHODS
Post-keratoplasty residual corneoscleral rims and/or the expired donor corneoscleral buttons were included for the purpose of this study. Initially, inverted rims were used to demonstrate the basic angle anatomy on a slit lamp bio-microscope. Central hazy cornea was then replaced with an artificial cornea and an artificial anterior chamber to simulate indirect gonioscopy, direct gonioscopy, goniotomy, and other angle-based surgeries. Direct gonioscopy and goniotomy exercises (as a means to simulate intraoperative gonioscopy and other angle-based surgeries respectively) were evaluated quantitatively, and the rest qualitatively.
RESULTS
A total of 65 residents were included in the exercise. The mean age was 26.69±1.74 years. Amongst these, 55 ophthalmology residents performed the basic examination, that is, slit lamp mounted angle anatomy examination (n=55) and artificial chamber mounted indirect gonioscopic examination through artificial cornea (n=55). In the second exercise, 10 glaucoma fellows performed the direct gonioscopic and the goniotomy exercises on artificial chamber. The fellows demonstrated a statistically significant improvement in interpretation and surgical skill enhancement concurrent with reduction in time taken with increasing number of attempts ( P <0.05). In the third simulation exercise, micro-stent placement within the Schlemm's canal, subconjunctival space, and the suprachoroidal space was re-produced successfully on multiple occasions.
CONCLUSIONS
The residual human corneoscleral rims proved to be an important resource for teaching both the basic examination skills and those required for transitioning to advanced intraoperative gonioscopy and goniotomy skills. These low cost, easy to adapt models can be incorporated within the curriculum for improved glaucoma training of both the residents and the glaucoma fellows.
More by Amar Pujari
View full profile →Smartphone Disc Photography Versus Standard Stereoscopic Disc Photography as a Teaching Tool.
A New Technique of iPhone 11 Pro Max Smartphone-aided Angle Video and Standstill Image Documentation.
Smartphone-aided Quantification of Iridocorneal Angle.
Top Research in Angle & Aqueous Outflow
Browse all →Anterior segment optical coherence tomography.
Primary angle closure glaucoma: What we know and what we don't know.
Surgical Outcomes of Gonioscopy-assisted Transluminal Trabeculotomy (GATT) in Patients With Open-angle Glaucoma.
Discussion
Comments and discussion will appear here in a future update.