Utility of Central 10 Degrees Visual Field Test With Size V Stimulus in End-Stage Glaucoma.
Summary
The central 10-degree visual field test with a size V stimulus provided more information than the test with a size III stimulus in end-stage glaucoma.
Abstract
PRCIS
In end-stage glaucoma, the central 10-degree visual field test with a size V stimulus provided useful information, including the number of points with detectable retinal sensitivity threshold values and retinal sensitivity threshold values.
PURPOSE
The purpose of this study was to evaluate the clinical utility of the central 10-degree visual field test with a size V stimulus in end-stage glaucoma.
MATERIALS AND METHODS
A total of 73 eyes with end-stage glaucoma (visual field limited to a radius of <10 degrees from fixation) were included. Central 10 degrees visual field tests were performed using both size III and V stimuli. Reliability indices, test duration, number of points with detectable retinal sensitivity threshold values, and retinal sensitivity threshold values at 4 central points, 4 quadrants, and 3 clusters (papillomacular area, superior half, and inferior half) were compared between the test results using size III and V stimuli.
RESULTS
When the size V stimulus was used, the mean test duration increased from 7.8 to 13.3 minutes ( P < 0.001), the mean number of test points with detectable retinal sensitivity threshold values in total area increased from 19.0 to 37.3 ( P < 0.001), and the mean retinal sensitivity threshold values in total area increased from 3.9 to 9.3 dB ( P < 0.001) compared with the test results with the size III stimulus. Significant increase in the visual field parameters was found in all quadrants and clusters ( P < 0.001), and a greater increase was associated with better visual acuity and greater mean deviation of the visual field ( P < 0.05).
CONCLUSIONS
The central 10-degree visual field test with a size V stimulus provided more information than the test with a size III stimulus in end-stage glaucoma.
More by Young Hoon Hwang
View full profile →Consistency of Bruch Membrane Opening Detection as Determined by Optical Coherence Tomography.
Membrane-tube-type glaucoma shunt device for refractory glaucoma surgery.
Novel membrane-tube type glaucoma shunt device for glaucoma surgery.
Top Research in Visual Field
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Improving our understanding, and detection, of glaucomatous damage: An approach based upon optical coherence tomography (OCT).
In the Knowledge Library
Discussion
Comments and discussion will appear here in a future update.