Diagnostic Abilities of Three-Dimensional Anterior Segment Optical Coherence Tomography in Detecting Angle Closure.
Sunee Chansangpetch, Phichayut Phinyo, Jayanton Patumanond, Janejit Choovuthayakorn, Shan C Lin
Summary
The 3D-angle parameters had high performance in detecting angle closure. However, comparing a horizontal measurement to 3D parameters, the AUC improvement was mostly insignificant.
Abstract
PRCIS
Three-dimensional (3D) angle parameters and cutoff values for detecting angle closure were proposed. The 3D parameters demonstrated excellent diagnostic performance. Certain horizontal two-dimensional (2D) parameters [ie, trabecular iris space area (TISA)-750, angle opening distance (AOD)-750, and AOD-500] can attain similar performance to their high-performing 3D counterparts.
OBJECTIVE
To investigate the diagnostic performance of single horizontal 2D versus 3D angle parameters from swept-source anterior segment optical coherence tomography (CASIA2) in detecting angle closure.
MATERIALS AND METHODS
The cross-sectional study included 118 phakic patients (59 open angles, 59 closed angles). AOD, angle recess area (ARA), and TISA at 250, 500, and 750 μm from scleral spur were measured in 360-degree radial-scan images. The 3D information of each measurement was analyzed in 2 patterns: (1) average 3D parameter-the averaged value from 360-degree angle values and (2) estimate 3D parameter-the estimation of surface area of circumferential angle inlet (using AOD) or circumferential angle volume (using ARA and TISA). The areas under the receiver operating characteristic curve [areas under the curve (AUCs)] of eighteen 3D parameters were compared with 2D horizontal parameters.
RESULTS
Among 3D parameters, AOD-500 estimate 3D gave the highest AUC (AUC: 0.950, cutoff: 6.09 mm 2 ), followed by AOD-750 estimate 3D (AUC: 0.948, cutoff: 8.26 mm 2 ). 3D parameters significantly increased the AUC of ARA-250 and TISA-250 (all P < 0.02) compared with the 2D parameters. No significant improvement in AUC was demonstrated for AOD-250 and all parameters at 500 and 750 μm. No significant difference in AUC was found among the 6 maximum AUC parameters, which were AOD-750 horizontal 2D, AOD-500 estimate 3D, TISA-750 horizontal 2D, AOD-500 horizontal 2D, AOD-750 estimate 3D, and TISA-750 average 3D.
CONCLUSIONS
The 3D-angle parameters had high performance in detecting angle closure. However, comparing a horizontal measurement to 3D parameters, the AUC improvement was mostly insignificant.
More by Sunee Chansangpetch
View full profile →Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography.
Anterior Segment Imaging for Angle Closure.
Impact of Myopia on Corneal Biomechanics in Glaucoma and Nonglaucoma Patients.
Top Research in OCT & Imaging
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Deep learning in ophthalmology: The technical and clinical considerations.
Anterior segment optical coherence tomography.
In the Knowledge Library
Discussion
Comments and discussion will appear here in a future update.