Assessing the Efficacy of Synthetic Optic Disc Images for Detecting Glaucomatous Optic Neuropathy Using Deep Learning.
Summary
Although our model performed well on synthetic data, training on a mixed data set demonstrated better performance and generalization.
Abstract
PURPOSE
Deep learning architectures can automatically learn complex features and patterns associated with glaucomatous optic neuropathy (GON). However, developing robust algorithms requires a large number of data sets. We sought to train an adversarial model for generating high-quality optic disc images from a large, diverse data set and then assessed the performance of models on generated synthetic images for detecting GON.
METHODS
A total of 17,060 (6874 glaucomatous and 10,186 healthy) fundus images were used to train deep convolutional generative adversarial networks (DCGANs) for synthesizing disc images for both classes. We then trained two models to detect GON, one solely on these synthetic images and another on a mixed data set (synthetic and real clinical images). Both the models were externally validated on a data set not used for training. The multiple classification metrics were evaluated with 95% confidence intervals. Models' decision-making processes were assessed using gradient-weighted class activation mapping (Grad-CAM) techniques.
RESULTS
Following receiver operating characteristic curve analysis, an optimal cup-to-disc ratio threshold for detecting GON from the training data was found to be 0.619. DCGANs generated high-quality synthetic disc images for healthy and glaucomatous eyes. When trained on a mixed data set, the model's area under the receiver operating characteristic curve attained 99.85% on internal validation and 86.45% on external validation. Grad-CAM saliency maps were primarily centered on the optic nerve head, indicating a more precise and clinically relevant attention area of the fundus image.
CONCLUSIONS
Although our model performed well on synthetic data, training on a mixed data set demonstrated better performance and generalization. Integrating synthetic and real clinical images can optimize the performance of a deep learning model in glaucoma detection.
TRANSLATIONAL RELEVANCE
Optimizing deep learning models for glaucoma detection through integrating DCGAN-generated synthetic and real-world clinical data can be improved and generalized in clinical practice.
More by Abadh K Chaurasia
View full profile →Long-term outcomes of glaucoma drainage devices for glaucoma post-vitreoretinal surgery with silicone oil insertion: a prospective evaluation.
In Vivo Analysis of Angle Dysgenesis in Primary Congenital, Juvenile, and Adult-Onset Open Angle Glaucoma.
Diagnostic Accuracy of Artificial Intelligence in Glaucoma Screening and Clinical Practice.
Top Research in Optic Nerve & Disc
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
In the Knowledge Library
Discussion
Comments and discussion will appear here in a future update.