Relating Standardized Automated Perimetry Performed With Stimulus Sizes III and V in Eyes With Field Loss Due to Glaucoma and NAION.
Summary
Censoring plus age correction is a valid method of comparison between size III and size V SAP VFs with moderate to severe VF loss due to optic nerve disorders.
Abstract
PURPOSE
Standard automated perimetry (SAP) visual field (VF) results are more repeatable using Goldmann stimulus size V (size V) in eyes with moderate/severe deficits due to glaucoma. There are few reports relating VFs using stimulus size V and III, typically used in the clinic for glaucoma, and none for non-arteritic anterior ischemic optic neuropathy (NAION). We hypothesized that we could compare and relate the VFs with both stimuli for glaucoma and NAION.
METHODS
We utilized 1992 same-day pairs of size III and size V SAP VFs using the 24-2 strategy for eyes with glaucoma or NAION. We explored the optimal threshold to censor the raw sensitivities, prior to calculating age-standardized total deviations (TDs). We determined the mean and standard deviation of the differences among all TD pairs. We computed a line of best fit to determine closeness to the line of unity.
RESULTS
The ideal censoring conversion threshold was 21 decibel (dB) for size III and 24 dB for size V. The difference between size V and size III censored (0.0 ± 1.9 dB) and uncensored (0.4 ± 2.6 dB) TD pairings highly correlate with each other (r2 = 0.70, P < 0.001). The line of best fit from these pairings has a slope of 0.92, which is close to that of the line of unity (m = 1).
CONCLUSIONS
Censoring plus age correction is a valid method of comparison between size III and size V SAP VFs with moderate to severe VF loss due to optic nerve disorders.
TRANSLATIONAL RELEVANCE
Size III and size V TDs are comparable in clinical practice.
More by David Szanto
View full profile →Archetypal Analysis Reveals Consistent Visual Field Patterns for Stimulus Sizes III and V in Glaucoma and NAION.
Optic Nerve Atrophy Conditions Associated With 3D Unsegmented Optical Coherence Tomography Volumes Using Deep Learning.
Archetypal Analysis Reveals Consistent Visual Field Patterns for Stimulus Size III and Size Modulation Perimetry in Glaucoma.
Top Research in Visual Field
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Improving our understanding, and detection, of glaucomatous damage: An approach based upon optical coherence tomography (OCT).
Discussion
Comments and discussion will appear here in a future update.