Randomized clinical trial of the 350-mm2 versus the 500-mm2 Baerveldt implant: longer term results: is bigger better?
Britt M T, LaBree L D, Lloyd M A, Minckler D S, Heuer D K, Baerveldt G et al.
This study found the 350-mm2 Baerveldt implant achieved better long-term intraocular pressure control than the 500-mm2 implant, guiding optimal surgical device selection for glaucoma.