Glaucoma Journal Club

In this database

29

2015 – 2026

DB Citations

408

across indexed articles

h-index

Not available

Total Citations

Not available

29 articles in Glaucoma Journal Club

Baseline Fourier-Domain Optical Coherence Tomography Structural Risk Factors for Visual Field Progression in the Advanced Imaging for Glaucoma Study.

Focal GCC and NFL loss as measured by FDOCT are the strongest predictors for VF progression among the measurements considered.

American journal of ophthalmology2016 Dec60 citations
optic-nervevisual-field

Swept-source OCT angiography imaging of the macular capillary network in glaucoma.

The assessment of macular VD by swept-source OCTA may offer additional information for detection of glaucoma.

The British journal of ophthalmology2017 Aug 949 citations
oct-imagingvisual-field

Micropulse Transscleral Diode Laser Cyclophotocoagulation in Refractory Glaucoma: Short-Term Efficacy, Safety, and Impact of Surgical History on Outcomes.

Micropulse transscleral diode laser cyclophotocoagulation has a significant short-term ocular hypotensive effect and favorable safety profile in eyes with refractory glaucoma.

Ophthalmology. Glaucoma201946 citations
glaucoma-surgeryiop-medical-therapy

Corneal Hysteresis for the Diagnosis of Glaucoma and Assessment of Progression Risk: A Report by the American Academy of Ophthalmology.

Corneal hysteresis is lower in glaucoma patients compared with normal subjects, and lower CH is associated with an increased risk of disease progression.

Ophthalmology2023 Apr29 citations
iop-medical-therapyglaucoma-diagnosis

Special Commentary: Reporting Clinical Endpoints in Studies of Minimally Invasive Glaucoma Surgery.

The suggested MCID for the cumulative probability of success for MIGS combined with CE-IOL at 2 years is 65%.

Ophthalmology2025 Feb25 citations
glaucoma-surgeryiop-medical-therapy

Quantitative Analysis of Retinal and Choroidal Vascular Parameters in Patients With Low Tension Glaucoma.

Eyes with low tension glaucoma seems to show a lower CC perfusion density, as well as a lower SVP and ONH+PP vessel length density compared to normal eyes.

Journal of glaucoma2019 Jun25 citations
oct-imagingoptic-nerve

Endoscopic cyclophotocoagulation versus second glaucoma drainage device after prior aqueous tube shunt surgery.

Both ECP and GDD-2 are both effective as second surgeries for refractory glaucoma that has failed a prior aqueous shunt.

Clinical & experimental ophthalmology2017 Apr25 citations
glaucoma-surgeryiop-medical-therapy

Trabecular Procedures Combined with Cataract Surgery for Open-Angle Glaucoma: A Report by the American Academy of Ophthalmology.

Trabecular procedures combined with cataract surgery provide an additional mild IOP reduction over cataract surgery alone in hypertensive OAG subjects.

Ophthalmology2024 Mar21 citations
iop-medical-therapyglaucoma-surgery

Novel and Semiautomated 360-Degree Gonioscopic Anterior Chamber Angle Imaging in Under 60 Seconds.

The newly introduced, semiautomated imaging system was able to document the full 360-degree iridocorneal angle views in normal and glaucoma eyes in less than 1 minute, which may allow longitudinal evaluation in a standardized manner.

Ophthalmology. Glaucoma201921 citations
glaucoma-surgeryangle-anatomy

Central Visual Field Testing in Early Glaucoma: A Report by the American Academy of Ophthalmology.

Evidence to date does not support routine testing using 10-2 VF for patients with early glaucoma.

Ophthalmology2024 Feb17 citations
visual-fieldoptic-nerve

Selective Laser Trabeculoplasty for the Treatment of Glaucoma: A Report by the American Academy of Ophthalmology.

Based on level I evidence, SLT is an effective long-term option for the treatment of open-angle glaucoma and is equivalent to ALT.

Ophthalmology2024 Jan17 citations
iop-medical-therapylaser-treatment

Clinical results of ab interno trabeculotomy using the trabectome in patients with uveitic glaucoma.

The trabectome AIT procedure appears to be effective in reducing IOP in uveitic glaucoma patients. Although no statistically significant difference was found in the number of glaucoma medications, a decreasing trend was found.

Clinical & experimental ophthalmology2020 Jan16 citations
glaucoma-surgeryiop-medical-therapy

Implantation of a second glaucoma drainage device.

With up to 3 years of follow-up, a second glaucoma drainage device was successful in reducing IOP to below 21 mmHg, but not as successful below 18 mmHg.

Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie2017 May13 citations
iop-medical-therapy

Endoscopic Cyclophotocoagulation and Other Cyclodestructive Methods: Histopathologic Comparison of In Vivo Treatment in Humans and Monkeys.

Treatment with ECP results in less overall tissue destruction and a targeted effect on the pigmented ciliary epithelium of the ciliary processes when compared with TCP.

Ophthalmology. Glaucoma201912 citations
glaucoma-surgery

Identification and Characterization of Imaging Technique Errors and Artifacts Using Anterior-Segment OCT for Irido-Corneal Angle Evaluations in Glaucoma.

This large-scale study presents the types and frequency of TEA found in AS-OCT-derived angle images.

Ophthalmology. Glaucoma201911 citations
oct-imagingangle-anatomy

Comparison and Correlation of Retinal Sensitivity Between Microperimetry and Standard Automated Perimetry in Low-tension Glaucoma.

Retinal sensitivity measurements obtained by the MP-3 microperimetry instrument and the standard automated HFA perimeter were similar and highly correlated in patients with LTG.

Journal of glaucoma2020 Oct8 citations
visual-fieldquality-of-life

Aqueous Shunts with Extraocular Reservoir for Open-Angle Adult Glaucoma: A Report by the American Academy of Ophthalmology.

Implantation of aqueous shunts with extraocular reservoir, including valved or nonvalved devices, has been shown to be an effective strategy to lower IOP.

Ophthalmology2024 Feb4 citations
glaucoma-surgeryiop-medical-therapy

Efficacy of Combined Suprachoroidal Stent and Cataract Surgery in Patients With Glaucoma.

Combined CyPass Micro-Stent implantation and cataract surgery may reduce glaucoma medication burden with a success rate of 28% to 42% at 1 year.

Journal of glaucoma2020 Aug3 citations
iop-medical-therapy

Reversible Venting Stitch for Fenestrating Valve-less Glaucoma Shunts.

The venting stitch valveless shunt modification allows for effective, reliable, and safe control of early postoperative IOP.

Journal of glaucoma2017 Dec3 citations
iop-medical-therapyglaucoma-surgery

Pilot Study of Lamina Cribrosa Intensity Measurements in Glaucoma Using Swept-Source Optical Coherence Tomography.

Intensity measurement of the LC is a potential novel parameter which warrants further study in the setting of glaucoma.

Journal of glaucoma2017 Feb3 citations
optic-nervevisual-field

Primary Open-Angle Glaucoma Preferred Practice Pattern®.

Ophthalmology2026 Feb 9
glaucoma-diagnosis

Primary Open-Angle Glaucoma Suspect Preferred Practice Pattern®.

Ophthalmology2026 Feb 9
glaucoma-diagnosis

Endoscopic Visualization for Atypical Uveitis Glaucoma Hyphema Syndrome Management.

Also, it showed that the capsular bag had inadequate zonular support to attempt repositioning the haptic into the bag.

Journal of glaucoma2023 Feb 1

Clinical results of ab interno trabeculotomy using the Trabectome in patients with pigmentary glaucoma compared to primary open angle glaucoma.

Trabectome provides similar outcomes to PG patients and POAG patients.

Clinical & experimental ophthalmology2016 Sep
glaucoma-surgeryiop-medical-therapy

Regression Analysis of Optical Coherence Tomography Disc Variables for Glaucoma Diagnosis.

Our various regression approaches were not able to significantly improve disc-based OCT glaucoma diagnosis.

Journal of glaucoma2016 Aug
optic-nerveoct-imaging

Longitudinal and Cross-Sectional Analyses of Age Effects on Retinal Nerve Fiber Layer and Ganglion Cell Complex Thickness by Fourier-Domain OCT.

Longitudinal and cross-sectional analyses provided consistent rates of approximately 0.2% per year of age-related thinning in NFL and GCC thicknesses.

Translational vision science & technology2016 Mar
iop-medical-therapyoptic-nerve

Endoscopic Cyclophotocoagulation and Pars Plana Ablation (ECP-plus) to Treat Refractory Glaucoma.

The mean IOP was lowered by at least 61% after ECP-plus and IOP lowering was sustained over the follow-up period.

Journal of glaucoma2016 Mar
iop-medical-therapyglaucoma-surgery

Endoscopic Cycloplasty (ECPL) and Lens Extraction in the Treatment of Severe Plateau Iris Syndrome.

The ACD, AOD 500, and ICA all increased significantly (P<0.001).

Journal of glaucoma2016 Mar
angle-anatomyiop-medical-therapy

Refractory open-angle glaucoma after neodymium-yttrium-aluminum-garnet laser lysis of vitreous floaters.

Secondary open-angle glaucoma is a complication of Nd:YAG vitreolysis for symptomatic floaters that may present with an increase in intraocular pressure immediately, or many months after the surgery.

American journal of ophthalmology2015 Jan
iop-medical-therapylaser-treatment