Glaucoma Journal Club

In this database

12

2016 โ€“ 2022

DB Citations

290

across indexed articles

h-index

โ€”

Not available

Total Citations

โ€”

Not available

12 articles in Glaucoma Journal Club

Minimally invasive glaucoma surgery as primary stand-alone surgery for glaucoma.

, Irvine CA, USA), the ab interno gel Implant (XEN, Allergan, Dublin, Ireland) or supraciliary stenting (CyPass Micro-Stent, Alcon, Fort Worth, TX, USA) may lower the lowering intraocular pressure and/or topical medication burden in phakic or pseudophakic patients with glaucoma.

Clinical & experimental ophthalmology2017 May125 citations
glaucoma-surgeryquality-of-life

Standalone iStent Trabecular Micro-bypass Glaucoma Surgery: A Systematic Review and Meta-Analysis.

The results from these studies support the independent effect of the iStent trabecular bypass devices on IOP and medication burden over a duration of follow-up of up to 5 years.

Journal of glaucoma2021 Jul 145 citations
iop-medical-therapyglaucoma-surgery

Minimally invasive glaucoma surgery: Comparison of iStent with iStent inject in primary open angle glaucoma.

Both trabecular micro-bypass stents in this study were effective in reducing IOP and the burden of medication when combined with cataract surgery.

Clinical & experimental ophthalmology2019 Sep37 citations
iop-medical-therapyglaucoma-surgery

Glaucoma laser and surgical procedure rates in Australia.

There has been a substantial increase in laser trabeculoplasty procedures in Australia, following a decline between 1994 and 2003.

The British journal of ophthalmology2016 Dec24 citations

Ab Interno Gel Implant-associated Bleb-related Infection.

Bleb-related infections after ab interno gel implant insertion can occur. If infection is treated appropriately, good clinical outcomes are possible.

American journal of ophthalmology2018 May23 citations
glaucoma-surgeryiop-medical-therapy

The Safety and Efficacy of Supraciliary Stenting Following Failed Glaucoma Surgery.

Ab interno supraciliary stenting has a favorable safety profile and provides an effective approach to controlling IOP and reducing medication burden in eyes in which previous glaucoma surgery has failed.

American journal of ophthalmology2018 Jun12 citations
glaucoma-surgeryiop-medical-therapy

Primary Needling of the Ab Interno Gelatin Microstent Reduces Postoperative Needling and Follow-up Requirements.

Primary needling at the time of XEN gel stent insertion is associated with a significant reduction in the need for postoperative needling and postoperative clinic visits.

Ophthalmology. Glaucoma202111 citations
glaucoma-surgeryiop-medical-therapy

Bleb-associated endophthalmitis: Proportion, presentation, management and outcomes in Victoria, Australia.

Bleb-associated endophthalmitis is an uncommon complication following glaucoma filtration surgery. The proportion has remained stable over time. Visual outcomes remain poor.

Clinical & experimental ophthalmology2019 Jul8 citations
glaucoma-surgeryiop-medical-therapy

The changing glaucoma treatment paradigm.

Clinical & experimental ophthalmology2022 Mar5 citations

Differences in bleb morphology between trabeculectomy and deep sclerectomy.

Clinical & experimental ophthalmology2017 Sep
glaucoma-surgery

Selective Laser Trabeculoplasty Reduces Intraocular Pressure Peak in Response to the Water Drinking Test.

Patients with open-angle glaucoma and ocular hypertension treated with SLT have significantly reduced peak IOPs and fluctuation in IOP in response to the WDT.

Journal of glaucoma2016 Sep
iop-medical-therapylaser-treatment

Anxiety in visual field testing.

HVF testing induces more anxiety than HRT. Increased pretest anxiety may reduce HVF test reliability. Increased test experience or interventions aimed at reducing pretest anxiety may result in improved test reliability and accuracy.

The British journal of ophthalmology2016 Aug
visual-field