Graham Lee
City Eye Centre · Children's Health Queensland Hospital and Health Service
In this database
14
2016 – 2026
DB Citations
46
across indexed articles
h-index
29
OpenAlex (all works)
Total Citations
3,020
OpenAlex (all works)
14 articles in Glaucoma Journal Club
Visual fields in glaucoma: Where are we now?
Artificial Intelligence has been found to have high sensitivity and specificity compared to expert observers in detecting field abnormalities and progression as well as integrating structure with function.
Glaucoma Drainage Device Technique in a Cohort of Experienced Glaucoma Surgeons in Australia and New Zealand.
Although a wide range of practice patterns for GDD implantation exists among Australia and New Zealand Glaucoma Society surgeons, there are consistent techniques currently in use to optimize patient outcomes.
Glaucoma drainage device tube extension without the need for a tube extender device or angiocatheter.
Bilateral simultaneous presentation of Posner-Schlossman syndrome.
Patient Experience and Barriers to the Visual Field Test for Glaucoma.
Mental and physical barriers to visual field testing tolerability were identified in a predominantly elderly population with glaucoma.
Long-term limitations and complications of trans-scleral diode laser cycloablation for refractory glaucoma.
Cyclodiode is often utilised for end-stage glaucoma when the IOP is uncontrolled on medical treatment and drainage surgery is not indicated, resulting in long-term reduction of IOP and the number of medications, including acetazolamide.
Ab interno bleb needling revision: a new approach.
Management of iridocorneal endothelial syndrome from a corneal and glaucoma perspective.
YAG Laser Xen Stent Truncation.
Recurrent intraocular haemorrhage due to pars plana Baerveldt glaucoma drainage device.
Angle-closure glaucoma following Descemet's stripping endothelial keratoplasty secondary to intraoperative floppy iris syndrome.
Hydrus microstent versus triple iStent inject W combined with phacoemulsification for glaucoma management: three-year outcomes.
This study has shown that both HM and TiSW provide effective IOP reduction and medication reduction in glaucoma patients undergoing combined cataract surgery at up to 3 years follow-up.
Clinicopathologic Examination of Translucent Refractile Intraluminal Tissue Coagulum From the Proximal Tube of a Baerveldt Glaucoma Drainage Device.
One possible cause of the refractile material within the specimen is spalled particles of silicone, presumably from the tube.
Glaucoma shunt oculodynia.