Luca Rossetti
AOL (United States) · Innsbruck Medical University · University of Milan
In this database
9
2018 – 2025
DB Citations
113
across indexed articles
h-index
42
OpenAlex (all works)
Total Citations
20,398
OpenAlex (all works)
9 articles in Glaucoma Journal Club
A Comparison between the Compass Fundus Perimeter and the Humphrey Field Analyzer.
Relative diagnostic precision of the 2 devices is equivalent. Test-retest variability of MS for CMP was better than for HFA.
Revisiting the Drasdo Model: Implications for Structure-Function Analysis of the Macular Region.
The Drasdo model can effectively account for AL assuming geometric scaling. Method 2 should be used for structure-function analyses.
Improving Visual Field Examination of the Macula Using Structural Information.
Binary responses can be modeled to incorporate detailed structural information from macular OCT into visual field testing, improving overall speed and accuracy in poor responders.
Do Additional Testing Locations Improve the Detection of Macular Perimetric Defects in Glaucoma?
Visual field examinations with additional macular locations can improve the detection of macular defects in GON modestly without loss of specificity when appropriate criteria are selected.
Spatial Summation in the Glaucomatous Macula: A Link With Retinal Ganglion Cell Damage.
Macular sensitivity loss in glaucoma is better described by a model in which RA changes with RGC loss. Structural measurements have limited dynamic range.
Visual Field Endpoints Based on Subgroups of Points May Be Useful in Glaucoma Clinical Trials: A Study With the Humphrey Field Analyzer and Compass Perimeter.
Restricting analysis to particular subsets of points of interest in the VF after censoring points with low sensitivity, as compared with using the familiar total field MD, can provide outcome measures with a broader range…
Systematic and Random Mapping Errors in Structure - Function Analysis of the Macula.
Rotating the perimetric grid to match the fovea-disc axis is not recommended. Fixation eccentricity and instability should be taken into account for structure-function analyses.
Comparison Between 24-2 ZEST and 24-2 ZEST FAST Strategies in Glaucoma and Ocular Hypertension Using a Fundus Perimeter.
ZEST FAST thresholding provides similar results to ZEST with a significantly reduced examination time.
Reliability of Self-Monitoring of Intraocular Pressure With iCare Home2 Rebound Tonometry.
Self-measured IOP with rebound tonometry showed good reliability and repeatability when compared with physician-measured IOP with both standard GAT and rebound tonometry.