Ueda Kaori
In this database
7
2015 – 2024
DB Citations
77
across indexed articles
h-index
—
Not available
Total Citations
—
Not available
7 articles in Glaucoma Journal Club
Comparison of efficacy and early surgery-related complications between one-quadrant and two-quadrant microhook ab interno trabeculotomy: a propensity score matched study.
The 1-year success rate was not significantly different between 1- and 2-quadrant incisions of microhook TLO. However, the 2-quadrant TLO showed significantly higher proportion of post-surgical transient IOP elevation.
Association of the prolonged use of anti-glaucoma medications with the surgical failure of ab interno microhook trabeculotomy.
The prolonged use of multiple glaucoma drugs adversely affected the outcome of μTLO at least at 1 year postoperatively.
En Face Slab Images Visualize Nerve Fibers With Residual Visual Sensitivity in Significantly Thinned Macular Areas of Advanced Glaucomatous Eyes.
En face slab images of maculae were able to reveal the residual nerve fiber bundles in the eyes with advanced glaucoma despite the GCL+IPL thickness in the maculae being diffusely and substantially reduced.
Three-year outcome of sulcus fixation of Baerveldt glaucoma implant surgery.
Sulcus fixation of BGI was effective for IOP reduction. However, ECD decreased over time.
Discordance of Disc-Fovea Raphe Angles Determined by Optical Coherence Tomography and MP-3 Microperimetry in Eyes With a Glaucomatous Hemifield Defect.
The structural temporal raphe was more deviated to the perimetrically normal hemiretina side than to the functional temporal raphe, thereby suggesting that a structural change may precede a functional loss.
Impact of glaucoma medications on subsequent Schlemm's canal surgery outcome: Cox proportional hazard model and propensity score-matched analysis.
Our study suggests that preoperative medications that do not involve conventional pathway outflow have a detrimental effect on subsequent Schlemm's canal surgery outcomes.
The Ability of SD-OCT to Differentiate Early Glaucoma With High Myopia From Highly Myopic Controls and Nonhighly Myopic Controls.
The abilities of the three OCT instruments to detect early glaucomatous eyes with high myopia were different if the normal eyes were associated with high myopia or not.