Global Search

Search articles, concepts, and chapters

Acta OphthalmolAugust 202023 citations

Changes in anterior lens density after Implantable Collamer Lens V4c implantation: a 4-year prospective observational study.

Yang Wen, Zhao Jing, Zhao Jiao, Shen Yang, Niu Lingling, A Ruma, Wang Xiaoying, Zhou Xingtao


AI Summary

This 4-year study found ICL V4c implantation safely corrects myopia, but anterior lens density slightly increased, though no cataracts developed. Clinical relevance: Monitor long-term lens changes.

Abstract

Purpose

To investigate the changes in anterior lens density with a Pentacam after Implantable Collamer Lens (ICL) V4c implantation in patients with myopia.

Methods

This prospective case series examined 62 eyes of 32 patients (mean age, 28.5 ± 5.73 years) with myopia or myopic astigmatism after ICL V4c implantation. Uncorrected distance vision acuity, corrected distance vision acuity (CDVA), manifest refraction, intraocular pressure, anterior chamber depth (ACD), anterior chamber volume (ACV), anterior chamber angle (ACA), endothelial cell density and Pentacam images of lens density were obtained pre- and postoperatively. The vault was obtained during the follow-ups.

Results

Patients were followed up for an average of 51 ± 2.7 months (range, 48-57 months). All surgeries were uneventful, without any complication. The efficacy and safety indices at the last follow-up were 1.03 ± 0.2 and 1.22 ± 0.22, respectively. No eye had decreased CDVA, and 66% eyes gained ≥1 line. Furthermore, refractive error in 90% eyes was within ±0.50 D and that of 100% was within ±1.0 D of the attempted refraction. Anterior average lens density (a-ALD) in the 0.5-, 1.0- and 1.5-mm depth zones increased by 10.41 ± 11.51%, 17.1 ± 11.09% and 16.76 ± 10.4%, respectively, compared to preoperative values (all p < 0.05). The change in a-ALD between two different age groups was not significant. Moreover, there were no significant correlations between the change in a-ALD and age, preoperative spherical equivalent, ACD, ACA, ACV or vault.

Conclusions

Implantable Collamer Lens (ICL) V4c implantation demonstrates safety and efficacy for myopia correction. Although a-ALD increased slightly at 4 years postoperatively, no cataract developed during the follow-up. Further studies should investigate the reason for the postoperative increase in a-ALD.


MeSH Terms

AdultAnterior ChamberFemaleHumansLens Implantation, IntraocularLongitudinal StudiesMaleMyopiaPhakic Intraocular LensesProspective StudiesVisual Acuity

Key Concepts6

Implantable Collamer Lens (ICL) V4c implantation in patients with myopia or myopic astigmatism demonstrated safety and efficacy for myopia correction, with an average follow-up of 51 ± 2.7 months (range, 48-57 months).

TreatmentCase seriesProspective case seriesn=62 eyes of 32 patientsCh27Ch44

For patients undergoing Implantable Collamer Lens (ICL) V4c implantation for myopia correction, the efficacy index at the last follow-up (average 51 ± 2.7 months) was 1.03 ± 0.2 and the safety index was 1.22 ± 0.22.

TreatmentCase seriesProspective case seriesn=62 eyes of 32 patientsCh27Ch44

After Implantable Collamer Lens (ICL) V4c implantation for myopia correction, no eye had decreased corrected distance vision acuity (CDVA), and 66% of eyes gained ≥1 line at an average of 51 ± 2.7 months postoperatively.

TreatmentCase seriesProspective case seriesn=62 eyes of 32 patientsCh27Ch44

Refractive error in 90% of eyes was within ±0.50 D and that of 100% of eyes was within ±1.0 D of the attempted refraction after Implantable Collamer Lens (ICL) V4c implantation for myopia correction at an average of 51 ± 2.7 months postoperatively.

TreatmentCase seriesProspective case seriesn=62 eyes of 32 patientsCh27Ch44

Anterior average lens density (a-ALD) in the 0.5-, 1.0- and 1.5-mm depth zones increased by 10.41 ± 11.51%, 17.1 ± 11.09% and 16.76 ± 10.4%, respectively, compared to preoperative values (all p < 0.05) after Implantable Collamer Lens (ICL) V4c implantation at 4 years postoperatively, though no cataract developed during the follow-up.

PrognosisCase seriesProspective case seriesn=62 eyes of 32 patientsCh19Ch27

There were no significant correlations between the change in anterior average lens density (a-ALD) and age, preoperative spherical equivalent, anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), or vault after Implantable Collamer Lens (ICL) V4c implantation.

MechanismCase seriesProspective case seriesn=62 eyes of 32 patientsCh19Ch27

Is this article assigned to the wrong chapter(s)? Let us know.