Anchor-assisted capsular bag IOL implantation to correct subluxated lenses in children with Marfan syndrome: long-term follow-up.
Yehezkeli Veronika, Greenbaum Eran, Belkin Avner, Assia Ehud I, Crystal-Shalit Ornit, Ela-Dalman Noa
AI Summary
The AssiAnchor device effectively stabilized subluxated lenses in pediatric Marfan syndrome, showing good long-term visual/refractive outcomes and IOL stability, offering a viable surgical option despite some complications like amblyopia.
Abstract
Purpose
To assess the long-term visual and refractive outcomes and potential complications of scleral bag fixation using the AssiAnchor device in pediatric patients with Marfan syndrome (MFS).
Setting
Department of Ophthalmology, Meir Medical Center, Kfar Saba, Israel.
Design
Retrospective, consecutive case series.
Methods
Data was collected on pediatric patients with genetically or clinically confirmed MFS who underwent lens extraction with intraocular lens (IOL) implantation and bag preservation using the AssiAnchor device.
Results
A total of 10 eyes of 8 patients were included. Mean postoperative follow-up was 5.08 years (range 2 to 9.25 years). Average age at surgery was 6.9 ± 3.3 years (range 2.8 to 13.75). The mean corrected distance visual acuity improved from 20/80 to 20/30 ( P = .01). Mean absolute error from the aimed refraction was -0.37 ± 0.6 diopters (D) (range -1.25 to 0.75 D). At the last follow-up, all IOLs were stable and central, with healthy conjunctival tissue over the sutures and flanges. Postoperative complications included glaucoma in 1 eye and IOL subluxation in 2 eyes of the same patient. Posterior capsular opacification occurred in 6 eyes, strabismus developed in 1 patient and resolved in 2 patients. Amblyopia was identified in 6 eyes (60%), comprising 5 mild cases and 1 moderate case.
Conclusions
The capsular anchor device effectively managed lens subluxation in pediatric MFS, providing long-term stabilization of the capsular bag and facilitated IOL implantation. The findings demonstrate satisfactory visual and refractive outcomes with an acceptable rate of complications.
MeSH Terms
Shields Classification
Key Concepts4
The capsular anchor device effectively managed lens subluxation in pediatric Marfan syndrome (MFS), providing long-term stabilization of the capsular bag and facilitated intraocular lens (IOL) implantation.
The mean corrected distance visual acuity improved from 20/80 to 20/30 (P = .01) in pediatric patients with Marfan syndrome (MFS) who underwent lens extraction with intraocular lens (IOL) implantation and bag preservation using the AssiAnchor device.
The mean absolute error from the aimed refraction was -0.37 ± 0.6 diopters (D) (range -1.25 to 0.75 D) in pediatric patients with Marfan syndrome (MFS) who underwent lens extraction with intraocular lens (IOL) implantation and bag preservation using the AssiAnchor device.
Postoperative complications in pediatric patients with Marfan syndrome (MFS) who underwent lens extraction with intraocular lens (IOL) implantation and bag preservation using the AssiAnchor device included glaucoma in 1 eye, IOL subluxation in 2 eyes of the same patient, posterior capsular opacification in 6 eyes, strabismus development in 1 patient, and amblyopia in 6 eyes (60%, 5 mild, 1 moderate).
Related Articles5
Postoperative complications and axial length growth after bilateral congenital cataract surgery: eyes with microphthalmos compared to a comparison group.
Case-Control StudySpherophakia, nanophthalmia, hypoplastic ciliary body and glaucoma in brachydactyly-associated syndromes.
Case SeriesClinical characteristics and treatment of 22 eyes of morning glory syndrome associated with persistent hyperplastic primary vitreous.
Case SeriesIris neovascularization and neovascular glaucoma in neurofibromatosis type 1: report of 3 cases in children.
Case SeriesOcular Features of Cerebro-Costo-Mandibular Syndrome.
Case ReportIs this article assigned to the wrong chapter(s)? Let us know.