Thermography: a new option to monitor filtering bleb function?
Matthias K J Klamann, Anna-Karina B Maier, Johannes Gonnermann, Julian P Klein, Peter Ruokonen, Uwe Pleyer
Summary
Temperature decrease in the filtering bleb provides information about its function.
Abstract
PURPOSE
To evaluate the filtering bleb function after trabeculectomy using a new ocular surface thermography device.
METHODS
Thirty-five eyes of 35 patients after trabeculectomy were included in this prospective study. The filtering bleb function was tested with a new ocular surface-oriented, infrared radiation thermographic device in a noncontact manner (TG 1000). The eyes were classified into poorly controlled and well-controlled intraocular pressure (IOP) groups according to the patients' postoperative IOP. According to Kawasaki and colleagues, the mean temperature decrease in the filtering bleb (TDB) for evaluating bleb function was used, where TDB=(mean temperature of the temporal and nasal bulbar conjunctiva)-(mean temperature of the filtering bleb). Furthermore, the filtering bleb was evaluated during 10 seconds of eye opening and a new parameter was introduced, the TB10sec. TDB and TB10sec were analyzed statistically.
RESULTS
The TDB was 0.911°C (±0.467) and the TB10sec was -1.027°C (±0.312) in the well-controlled IOP group. The TDB was 0.599°C (±0.499), and the TB10sec was -0.623°C (±0.265) in the poorly controlled IOP group, respectively. The difference in TDB (P=0.045), as well as that of TB10sec (P<0.001), between the well-controlled and poorly controlled IOP groups was significant.
CONCLUSIONS
Temperature decrease in the filtering bleb provides information about its function. Because of the easy handling and reproducible measurements, thermography using Tomey TG 1000 may be a useful tool in the evaluation of filtering bleb function.
More by Matthias K J Klamann
View full profile →Contralateral eye comparison study in MICS & MIGS: Trabectome® vs. iStent inject®.
Intraocular Pressure Measurements After Descemet Membrane Endothelial Keratoplasty.
Is there a change in the quality of life comparing the micro-invasive glaucoma surgery (MIGS) and the filtration technique trabeculectomy in glaucoma patients?
Top Research in Glaucoma Surgery
Browse all →Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
Efficacy, Safety, and Risk Factors for Failure of Standalone Ab Interno Gelatin Microstent Implantation versus Standalone Trabeculectomy.
Prospective, Randomized, Controlled Pivotal Trial of an Ab Interno Implanted Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract: Two-Year Results.
Discussion
Comments and discussion will appear here in a future update.