Novel Parameter of Corneal Biomechanics That Differentiate Normals From Glaucoma.
Summary
Glaucomatous eyes have a greater mean outward applanation velocity and peak distance, but shorter time to highest concavity than eyes without glaucoma.
Abstract
PURPOSE
To identify novel corneal biomechanical parameters differentiating glaucomatous from normal eyes.
PATIENTS AND METHODS
Sixty subjects with varying degrees of glaucoma severity and 61 normal controls underwent corneal biomechanical measurements including corneal deformation amplitude, inward and outward applanation length and velocity, and highest concavity time in 1 eye per subject at Queen Mary Hospital, Hong Kong. Measurements were taken with the Corvis ST device, a noncontact tonometer coupled with a high-speed Scheimpflug camera. The intraocular pressure (IOP) and central corneal thickness (CCT) were also measured.
RESULTS
Significant findings included differences in outward applanation velocity (glaucoma: -0.37±0.01 m/s; control: -0.32±0.01 m/s; P=0.001), peak distance (glaucoma: 2.37±0.03 mm; control: 2.30±0.02 mm; P=0.005), and highest concavity time (glaucoma: 16.75±0.08 ms; control: 17.05±0.07 ms; P=0.002) between the 2 groups, after correcting for IOP, CCT, and age. Both outward applanation velocity and peak distance were moderately correlated with IOP and CCT. However, highest concavity time was not correlated with either IOP or CCT (R(2)=0.0140 and 0.000055, respectively). Age was not correlated with any of the 3 parameters.
CONCLUSIONS
Glaucomatous eyes have a greater mean outward applanation velocity and peak distance, but shorter time to highest concavity than eyes without glaucoma. The difference in time to highest concavity does not correlate with age, IOP, or CCT, suggesting that this parameter may be a marker of increased pressure susceptibility that is independently associated with glaucoma risk.
More by Rachel Lee
View full profile →Readability and Suitability of Online Patient Education Materials for Glaucoma.
Open Conjunctival Approach for Sub-Tenon's Xen Gel Stent Placement and Bleb Morphology by Anterior Segment Optical Coherence Tomography.
Use of Diagnostic Codes for Primary Open-Angle Glaucoma Polygenic Risk Score Construction in Electronic Health Record-Linked Biobanks.
Top Research in Cornea & Biomechanics
Browse all →The impact of chronic use of prostaglandin analogues on the biomechanical properties of the cornea in patients with primary open-angle glaucoma.
Corneal Biomechanics and Visual Field Progression in Eyes with Seemingly Well-Controlled Intraocular Pressure.
Evaluation of a New Rebound Self-tonometer, Icare HOME: Comparison With Goldmann Applanation Tonometer.
Discussion
Comments and discussion will appear here in a future update.