Evaluation of Nonmydriatic Hand-held Optic Disc Photography Grading in the Philadelphia Glaucoma Detection and Treatment Project.
Michael Waisbourd, Emily A Bond, Timothy Sullivan, Wanda D Hu, Sonya B Shah, Jeanne Molineaux, Harjeet Sembhi, George L Spaeth, Jonathan S Myers, Lisa A Hark, L Jay Katz
Summary
Nonmydriatic, monoscopic disc photographs obtained by a hand-held camera had only moderate disc grading reproducibility.
Abstract
PURPOSE
To determine the reproducibility of optic disc photograph grading obtained by a hand-held fundus camera and to determine the diagnostic value of these photographs in detecting patients with glaucoma in a community-based glaucoma-detection program.
MATERIALS AND METHODS
Patients underwent slit-lamp examination by an ophthalmologist who graded each patient's optic discs using 2 methods: cup-to-disc ratio (CDR) and disc damage likelihood scale (DDLS). After a comprehensive glaucoma evaluation, patients were diagnosed as having "glaucoma," "glaucoma suspect," or "no glaucoma." Nonmydriatic, monoscopic optic disc photographs were then taken with a portable digital imaging device. On a different day, the same examiner and a second observer graded the disc photographs in a masked manner and determined a diagnostic impression based only on the disc photographs.
RESULTS
Of the 1649 patients examined, 119 subjects were randomly selected according to 3 groups of diagnoses: "glaucoma" (n=36), "glaucoma suspect" (n=50), and "no glaucoma" (n=33). For CDR, the intraobserver agreement was 0.71 and the interobserver agreement was 0.69. For disc DDLS, the intraobserver agreement was 0.65 and the interobserver agreement was 0.67. The area under the receiver-operating characteristic distinguishing between normal and glaucoma was 0.88 and 0.86 for CDR and disc DDLS, respectively.
CONCLUSIONS
Nonmydriatic, monoscopic disc photographs obtained by a hand-held camera had only moderate disc grading reproducibility. This could be due to a reduced quality of images, making interpretation more challenging, due to taking photographs through small pupils by a hand-held camera and the high percentage of patients with significant cataracts.
More by Michael Waisbourd
View full profile →Surgical Outcomes of Gonioscopy-assisted Transluminal Trabeculotomy (GATT) in Patients With Open-angle Glaucoma.
Clinical Efficacy and Safety Profile of Micropulse Transscleral Cyclophotocoagulation in Refractory Glaucoma.
Philadelphia Telemedicine Glaucoma Detection and Follow-up Study: Methods and Screening Results.
Top Research in Optic Nerve & Disc
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Discussion
Comments and discussion will appear here in a future update.