A New Expander for Schlemm Canal Surgery in Primary Open-angle Glaucoma-Interim Clinical Results.
Summary
Implantation of the Stegmann Canal Expander in canaloplasty lowered IOP significantly in POAG without complications related to the device in this 1-year observation period.
Abstract
PURPOSE
To evaluate a new canal expander in circumferential viscocanalostomy (canaloplasty) for whites with primary open-angle glaucoma (POAG).
DESIGN
Prospective, single-center, noncomparative study.
PARTICIPANTS
Twenty-two eyes of 22 consecutive patients with medically uncontrolled POAG underwent primary viscocanalostomy and implantation of the Stegmann Canal Expander into Schlemm canal with a follow-up time of at least 1 year.
MATERIALS AND METHODS
Schlemm canal was unroofed ab externo, and dilated with viscoelastic material and microcatheter. The Stegmann Canal Expander is a flexible, fenestrated hollow implant of 9 mm in length. One expander was implanted into either side of the surgically created of ostium to keep the Schlemm canal permanently open. The superficial scleral flap was closed watertight. Laser goniopuncture of the trabeculo-Descemet membrane window was performed if postoperative intraocular pressure (IOP) exceeded 16 mm Hg.
MAIN OUTCOME MEASURES
Complete successes were defined as a confirmed IOP≤21, ≤18, and ≤16 mm Hg without medications, respectively, combined with a 30% IOP reduction. Number of antiglaucomatous medications, best-corrected visual acuity, and intraoperative and postoperative complications were recorded.
RESULTS
The mean IOP dropped from 27.1±5.3 mm Hg preoperatively to 13.6±1.6 mm Hg at 6 months, 13.0±1.5 mm Hg at 9 months, and 13.1±2.2 mm Hg at 12 months (P<0.001). The complete success rates for an IOP≤21, ≤18, and ≤16 mm Hg combined with a 30% IOP reduction were 91% [95% confidence interval (CI), 0.80-1.0], 91% (95% CI, 0.80-1.0), and 91.0% (95% CI, 0.80-1.0) at 6 months, and 86% (95% CI, 0.73-1.0), 82% (95% CI, 0.67-1.0), and 82.0% (95% CI, 0.67-1.0) at 12 months. The success rate of an IOP≤16 mm Hg without medications did not depend on age [hazard ratios (HR) 1.02; 95% CI, 0.85-1.12; P=0.74], preoperative IOP (HR 0.97; 95% CI, 0.83-1.23; P=0.89), and mean visual defect (HR 1.05; 95% CI, 0.72-1.27; P=0.76). Laser goniopuncture was performed on 2 eyes (9%) 4.1 months postoperatively; the mean IOP was 19.5 mm Hg before and 13.6 mm Hg after goniopuncture. The number of medications dropped from 2.9±0.6 before surgery to 0.05±0.2 after surgery (P<0.001). The postoperative best-corrected visual acuity at last visit (0.12±0.09; range, 0 to 0.39) was comparable to preoperative values (mean±SD, 0.16±0.10; range, 0 to 0.39) (P=0.35). Minor intraoperative or postoperative complications included microhyphema (8 eyes) and transient elevated IOP (steroid responder; 2 eyes).
CONCLUSIONS
Implantation of the Stegmann Canal Expander in canaloplasty lowered IOP significantly in POAG without complications related to the device in this 1-year observation period.
More by Matthias C Grieshaber
View full profile →Canaloplasty with Stegmann Canal Expander for primary open-angle glaucoma: two-year clinical results.
Access to Schlemm's canal for canaloplasty: an intra-individual comparison of two dissection techniques.
Comparison of Outcomes of Deep Sclerectomy, Canaloplasty, and Viscocanaloplasty: A Multicenter Study.
Top Research in IOP & Medical Therapy
Browse all →The Complications of Myopia: A Review and Meta-Analysis.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
Discussion
Comments and discussion will appear here in a future update.