The use of Bruch's membrane opening-based optical coherence tomography of the optic nerve head for glaucoma detection in microdiscs.
Philip Enders, Friederike Schaub, Werner Adler, Roman Nikoluk, Manuel M Hermann, Ludwig M Heindl
Summary
In small optic discs, BMO-MRW and peripapillary RNFLT (OCT) have similar sensitivity to discriminate patients with glaucoma from normal controls; both exceed CSLT rim area in diagnostic power.
Abstract
PURPOSE
To assess the performance of Bruch's membrane opening (BMO)-based spectral domain optical coherence tomography (SD-OCT) of the optic nerve head for glaucoma detection in microdiscs in comparison with confocal scanning laser tomography (CSLT).
DESIGN
Retrospective cohort study.
METHODS
82 eyes of 82 patients with disc size <1.63 mmunderwent SD-OCT and CSLT measurements, visual field testing and clinical examination. BMO-based minimal rim width (BMO-MRW), retinal nerve fibre layer thickness (RNFLT) in SD-OCT and rim area measured in CSLT were compared and correlated with visual field defects.
RESULTS
51 patients with glaucoma, 11 patients with ocular hypertension (OHT) and 20 healthy controls had a mean disc area of 1.36±0.19 mmin CSLT, and BMO area was 1.45±0.22 mm(r=0.17; p=0.12). In patients with glaucoma, visual field mean defect was -7.5±6.7 dB. Global BMO-MRW correlated better with visual field function (Spearman's r=0.65; p<0.001) than RNFLT (r=0.58; p≤0.001) and CSLT rim area (r=0.47; p=0.004). BMO-MRW significantly deteriorated with progressive visual field loss (p<0.001). In receiver operating characteristic analysis, sensitivity of BMO-MRW was 68.6% at 95% specificity (area under curve (AUC)=0.87), similar to sensitivity of RNFLT (66.4%; AUC=0.81). Performance of CSLT rim area was significantly worse (AUC=0.70, p=0.008). In healthy controls, mean BMO-MRW was 344.3±64.1 µm, mean RNFLT 78.0±11.3 µm and CSLT mean rim area 1.07±0.18 mm.
CONCLUSIONS
In small optic discs, BMO-MRW and peripapillary RNFLT (OCT) have similar sensitivity to discriminate patients with glaucoma from normal controls; both exceed CSLT rim area in diagnostic power. In glaucomatous patients, BMO-MRW correlates strongest with visual field function.
Keywords
More by Philip Enders
View full profile →Novel Bruch's Membrane Opening Minimum Rim Area Equalizes Disc Size Dependency and Offers High Diagnostic Power for Glaucoma.
The novel role of lymphatic vessels in the pathogenesis of ocular diseases.
Evaluation of two-dimensional Bruch's membrane opening minimum rim area for glaucoma diagnostics in a large patient cohort.
Top Research in Optic Nerve & Disc
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Discussion
Comments and discussion will appear here in a future update.