Novel Bruch's Membrane Opening Minimum Rim Area Equalizes Disc Size Dependency and Offers High Diagnostic Power for Glaucoma.
Philip Enders, Werner Adler, Friederike Schaub, Manuel M Hermann, Thomas Dietlein, Claus Cursiefen, Ludwig M Heindl
Summary
Bruch's membrane opening-based minimum rim area measurements offer advantages compared to one-dimensional parameters assessing neuroretinal rim by SD-OCT.
Abstract
PURPOSE
The purpose of this study was to assess the diagnostic power of the novel two-dimensional parameter Bruch's membrane opening minimal rim area (BMO-MRA) in spectral-domain optical coherence tomography (SD-OCT) for detection of glaucoma compared to minimal rim width (BMO-MRW) and retinal nerve fiber layer (RNFL) thickness in large and small optic discs.
METHODS
In this case-control, cross-sectional study, 207 eyes of 207 participants, including 89 controls and 97 patients with glaucoma and 21 with ocular hypertension (OHT), with a disc size 2.43 mm2 underwent SD-OCT, confocal laser scanning tomography (CSLT), visual field testing, and clinical examination. Bruch's membrane opening-MRA BMO-MRW, RNFL thickness of SD-OCT and disc margin rim area (DM-RA) of CSLT were evaluated and analyzed for diagnostic power to detect glaucoma.
RESULTS
In healthy eyes with macrodiscs, mean BMO-MRW of 243.14 ± 43.12 μm was significantly smaller than BMO-MRW in microdiscs (338.97 ± 69.39; P < 0.001). Bruch's membrane opening-MRA was comparable between disc size groups with 1.22 ± 0.25 mm2 for macrodiscs and 1.26 ± 0.27 mm2 for microdiscs (P = 0.51), as was RNFL thickness (82.69 ± 15.76 μm versus 78.53 ± 11.01 μm, respectively; P = 0.28). Perimetric mean deviation was -8.7 ± 6.3 dB in glaucoma and -0.6 ± 1.60 dB in OHT patients. Correlation of BMO-MRA and visual field function was rho (ρ) = 0.70 (P < 0.001). Diagnostic power to differentiate glaucoma patients was highest for BMO-MRA. Partial area under the curve (pAUC) for BMO-MRA was 0.14 for specificity between 0.8 and 1.0, exceeding pAUCs of BMO-MRW (P < 0.001), RNFL thickness (P = 0.03), and DM-RA (P = 0.01).
CONCLUSIONS
Bruch's membrane opening-based minimum rim area measurements offer advantages compared to one-dimensional parameters assessing neuroretinal rim by SD-OCT. In nonglaucomatous eyes, BMO-MRA values seem comparable for the full range of disc sizes. Bruch's membrane opening-MRA surpasses other parameters in diagnostic power for glaucoma.
More by Philip Enders
View full profile →The novel role of lymphatic vessels in the pathogenesis of ocular diseases.
The use of Bruch's membrane opening-based optical coherence tomography of the optic nerve head for glaucoma detection in microdiscs.
Evaluation of two-dimensional Bruch's membrane opening minimum rim area for glaucoma diagnostics in a large patient cohort.
Top Research in Optic Nerve & Disc
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Discussion
Comments and discussion will appear here in a future update.