Trabeculectomy Combined With Collagen Matrix Implant (Ologen).
Summary
Trabeculectomy surgeries with Ologen performed by the same surgeon were effective in lowering IOP with a low complication rate at mid-term follow-up.
Abstract
PURPOSE OF THE STUDY
The purpose of the study was to report and evaluate outcomes of trabeculectomy with use of a subconjunctival biodegradable collagen matrix implant.
PATIENTS AND METHODS
Retrospective review of trabeculectomy with Ologen implant of 65 eyes of 58 patients by the same surgeon from October, 2011 to October, 2014. Exclusion criteria were <6 months of follow-up after surgery, and uveitic or neovascular glaucoma. Demographic characteristics of the study population, visual acuity, intraocular pressure (IOP), glaucoma medications, bleb characteristics, and early and late postoperative complications were recorded. Complete and qualified IOP control success, ≤15 and ≤18 mm Hg, was calculated with the Kaplan-Meier analysis.
RESULTS
The mean age of the patients in the study was 65.9±15.1 years. IOP was reduced from a mean of 21.4±9.2 to 12.3±3.7 mm Hg at the last follow-up visit (P<0.0001). The number of IOP-lowering medications per eye was reduced from a mean of 1.86 preoperatively to 0.2 at the last follow-up visit (P<0.0001). The Kaplan-Meier survival curves of complete success for IOP≤15 mm Hg and ≤18 mm Hg were 47.2% and 62.9%, respectively, at 36 months. Postoperative complications occurred in 15% of the eyes, with bleb leakage (6%) and hypotony (5%), which were resolved medically. At the last postoperative visit, blebs were described as normal (86.4%), flat (9.1%), and polycystic (4.5%).
CONCLUSIONS
Trabeculectomy surgeries with Ologen performed by the same surgeon were effective in lowering IOP with a low complication rate at mid-term follow-up.
More by Claudio I Perez
View full profile →Comparison of Anterior Segment Optical Coherence Tomography Parameters Among Vietnamese, Chinese, and Whites.
Efficacy of Cataract Surgery With Trabecular Microbypass Stent Implantation in Combined-Mechanism Angle Closure Glaucoma Patients.
Subconjunctival Injections of Mitomycin C Are Associated with a Lower Incidence of Hypertensive Phase in Eyes with Ahmed Glaucoma Valve.
Top Research in Glaucoma Surgery
Browse all →Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
Efficacy, Safety, and Risk Factors for Failure of Standalone Ab Interno Gelatin Microstent Implantation versus Standalone Trabeculectomy.
Prospective, Randomized, Controlled Pivotal Trial of an Ab Interno Implanted Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract: Two-Year Results.
Discussion
Comments and discussion will appear here in a future update.