J Glaucoma
J GlaucomaMarch 2017Journal Article

24-Hour Intraocular Pressure Rhythm in Patients With Untreated Primary Open Angle Glaucoma and Effects of Selective Laser Trabeculoplasty.

IOP & Medical TherapyLaser Treatment

Summary

After medical treatment wash-out, patients with open angle glaucoma consistently had a significant 24-hour IOP rhythm with nocturnal acrophase. SLT reduces the absolute IOP value but does not modify the nyctohemeral IOP rhythm.

Abstract

PURPOSE OF THE STUDY

The purpose of the study was to evaluate the 24-hour nyctohemeral rhythm of intraocular pressure (IOP) in patients with untreated primary open angle glaucoma using a contact lens sensor. To evaluate the effect of selective laser trabeculoplasty (SLT) on the 24-hour rhythm of IOP.

MATERIALS AND METHODS

Prospective study conducted in a chronobiology center. Fourteen patients with primary open angle glaucoma underwent three 24-hour IOP measurement sessions after a complete wash-out of the medical treatment: before SLT and 1 and 6 months after, using the contact lens sensor Triggerfish (SENSIMED, Lausanne, Switzerland). IOP and the main parameters of nyctohemeral rhythm (existence of a rhythm, acrophase, bathyphase, midline estimating statistic of rhythm, amplitude, and range) before SLT were compared with the same parameters measured 1 and 6 months later.

RESULTS

IOP increased from 16.3±3.7 to 22.1±8.4 mm Hg (5.8 mm Hg; 95% confidence interval (CI), 2.41-12.71; P=0.009) after the wash-out procedure. After SLT, IOP significantly decreased by 3.4 mm Hg (95% CI, 0.09-7.89; P=0.041) (14.9%) at 1 month and 1.9 mm Hg (95% CI 0.10-3.84; P=0.044) (8.1%) at 6 months. After medication wash-out, 100% of the subjects had a nyctohemeral IOP rhythm with nocturnal acrophase (01:57±3:32 AM, 01:22±3:01 AM, and 03:17±2:12 AM at inclusion, 1 and 6 mo, respectively). SLT did not significantly change the characteristics of the 24-hour IOP pattern, notably the amplitude and the type of rhythm (persistence of nocturnal acrophase).

CONCLUSIONS

After medical treatment wash-out, patients with open angle glaucoma consistently had a significant 24-hour IOP rhythm with nocturnal acrophase. SLT reduces the absolute IOP value but does not modify the nyctohemeral IOP rhythm.

Discussion

Comments and discussion will appear here in a future update.