Reproducibility of Central Corneal Thickness Measurements in Healthy and Glaucomatous Eyes.
Summary
CCT measurements exhibit intraday and interday variation, with the latter being significantly greater than the former. A single CCT assessment inadequately characterizes CCT and may impact risk assessment in patients with suspect and/or diagnosed glaucoma.
Abstract
PURPOSE
The purpose of this study is to characterize intraday and interday variation in central corneal thickness (CCT) in healthy and glaucomatous subjects.
METHODS
In this prospective cohort study, 40 healthy subjects and 42 subjects with primary open-angle glaucoma underwent CCT measurements by ultrasonic pachymetry on 5 days over 1 year: first at baseline, then at 1 week and 1, 6, and 12 months after baseline. On 1visit, CCT was measured every 2 hours from 08:00 to 20:00. Intraday CCT variance was compared with interday CCT variance.
RESULTS
Mean CCT at all visits and time points ranged from 561 to 574 µm in healthy eyes and from 548 to 563 µm in glaucomatous eyes. The mean intraday CCT range (highest minus lowest readings) was 21±10 µm in healthy participants and 21±10 µm in glaucoma patients. The mean interday CCT range was 27±13 µm in healthy participants and 24±14 µm in glaucoma patients. Within-subject variance was significantly larger among the interday CCT measurements than the intraday CCT measurements in both healthy subjects and glaucoma patients (P<0.0001 for both) demonstrating that measurements taken on separate days are more different than measurements taken on the same day. Interday CCT differences of ≥30 µm were seen in 27.7% of normal subjects and 30% of glaucoma patients.
CONCLUSIONS
CCT measurements exhibit intraday and interday variation, with the latter being significantly greater than the former. A single CCT assessment inadequately characterizes CCT and may impact risk assessment in patients with suspect and/or diagnosed glaucoma.
More by Tony Realini
View full profile →West Indies Glaucoma Laser Study (WIGLS): 1. 12-Month Efficacy of Selective Laser Trabeculoplasty in Afro-Caribbeans With Glaucoma.
The Effects of Glaucoma and Glaucoma Therapies on Corneal Endothelial Cell Density.
Low-energy Selective Laser Trabeculoplasty Repeated Annually: Rationale for the COAST Trial.
Top Research in Cornea & Biomechanics
Browse all →The impact of chronic use of prostaglandin analogues on the biomechanical properties of the cornea in patients with primary open-angle glaucoma.
Corneal Biomechanics and Visual Field Progression in Eyes with Seemingly Well-Controlled Intraocular Pressure.
Evaluation of a New Rebound Self-tonometer, Icare HOME: Comparison With Goldmann Applanation Tonometer.
Discussion
Comments and discussion will appear here in a future update.