Quantitative assessment of changes in anterior segment morphology after argon laser peripheral iridoplasty: findings from the EARL study group.
Summary
ALPI results in changes to the angle morphology and lowered IOP in eyes with residual angle closure. Our findings suggest a possible role for ALPI in eyes with residual angle closure following peripheral iridotomy.
Abstract
IMPORTANCE
Argon laser peripheral iridoplasty (ALPI) could be effective in widening residual angle closure following laser peripheral iridotomy (LPI).
BACKGROUND
We investigated changes in angle parameters following ALPI and its safety profile in this study.
DESIGN
Retrospective, observational case series.
PARTICIPANTS
The records from a single centre, of 36 patients (60 eyes) who underwent ALPI, for residual angle closure following LPI, were reviewed.
METHODS
We analysed anterior chamber parameters in anterior segment optical coherence tomography (ASOCT) images using customized software pre- and post-ALPI. Paired t-test was used to compare changes.
MAIN OUTCOME MEASURES
ASOCT parameters analysed included angle opening distance (AOD 500 and 750), trabecular iris surface area (TISA 500 and 750), anterior chamber width (ACW), anterior chamber volume (ACV), angle recess area (ARA), anterior chamber area (ACA), anterior chamber depth (ACD) and lens vault (LV).
RESULTS
There was a mean increase in AOD 500 (0.05 vs. 0.16 mm, P < 0.001), AOD 750 (0.15 vs. 0.27 mm, P < 0.001), TISA 500 (0.010 vs. 0.038 mm, P < 0.001), TISA 750 (0.039 vs. 0.102 mm, P < 0.001), ACV (89.76 vs. 102.25 mm, P = 0.01), ARA 500 (0.015 vs. 0.033 mm, P < 0.001) and ARA 750 (0.044 vs. 0.088 mm, P < 0.001). There was no significant change in ACW, ACD, ACA and LV. Mean intraocular pressure (IOP) decreased post-ALPI (17.2 vs. 15.7 mmHg, P = 0.002). The mean follow-up duration was 2.1 years (range 0.5-5 years).
CONCLUSIONS AND RELEVANCE
ALPI results in changes to the angle morphology and lowered IOP in eyes with residual angle closure. Our findings suggest a possible role for ALPI in eyes with residual angle closure following peripheral iridotomy.
Keywords
More by Dawn K Lim
View full profile →Two-Year Outcomes of the Paul Glaucoma Implant for Treatment of Glaucoma.
Three-Year Outcomes of the Paul Glaucoma Implant for Treatment of Glaucoma.
Efficacy and Safety of Repeated Micropulse Transscleral Diode Cyclophotocoagulation in Advanced Glaucoma.
Top Research in IOP & Medical Therapy
Browse all →The Complications of Myopia: A Review and Meta-Analysis.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
Discussion
Comments and discussion will appear here in a future update.