Swept-Source OCT for Evaluating the Lamina Cribrosa: A Report by the American Academy of Ophthalmology.
Hana L Takusagawa, Ambika Hoguet, Anna K Junk, Kouros Nouri-Mahdavi, Sunita Radhakrishnan, Teresa C Chen
Summary
Imaging of the lamina cribrosa using SS-OCT has demonstrated that the lamina cribrosa is likely biomechanically active and that significant changes occur in glaucoma.
Abstract
PURPOSE
To review the published literature on the use of swept-source (SS) OCT for evaluating the lamina cribrosa in glaucoma.
METHODS
A PubMed and Cochrane Library literature search initially conducted on March 3, 2017, and updated on June 26, 2018, yielded a total of 64 articles. Articles that were reviews or that were not published in English were excluded, and 29 were found to fit the inclusion criteria. The panel methodologist then assigned a level of evidence rating to each study. Fifteen studies were rated level III, 14 studies were rated level II, and no studies were rated level I.
RESULTS
Different aspects of the lamina cribrosa were studied using SS-OCT, including the anterior lamina cribrosa curvature, anterior lamina cribrosa depth, anterior lamina cribrosa insertions, laminar thickness, focal lamina cribrosa defects (FLCDs), and lamina cribrosa microarchitecture. In general, imaging of the anterior lamina can be achieved reliably, although shadowing from blood vessels at the neuroretinal rim remains an issue. Imaging of the posterior lamina can be achieved with varying levels of success. In glaucoma, there is posterior migration of the anterior lamina cribrosa insertions as well as increased thinning and posterior curvature of the lamina cribrosa. Focal lamina cribrosa defects appear more commonly in glaucoma, and this may hint at the pathogenesis of axonal damage. In addition, there may be remodeling of the microarchitecture of the lamina, resulting in more variable laminar pores. There are limited studies comparing SS-OCT with spectral-domain (SD) OCT with regard to imaging of the lamina, but the difference in image quality between enhanced depth imaging (EDI) with SD-OCT and SS-OCT seems minimal.
CONCLUSIONS
Imaging of the lamina cribrosa using SS-OCT has demonstrated that the lamina cribrosa is likely biomechanically active and that significant changes occur in glaucoma. The diagnostic utility of SS-OCT for lamina cribrosa imaging is promising, but standardized nomenclature, automated measurements, and longitudinal studies with larger and more diverse sample sizes are needed.
More by Hana L Takusagawa
View full profile →Projection-Resolved Optical Coherence Tomography Angiography of Macular Retinal Circulation in Glaucoma.
Spectral-Domain OCT: Helping the Clinician Diagnose Glaucoma: A Report by the American Academy of Ophthalmology.
OCT Angiography for the Diagnosis of Glaucoma: A Report by the American Academy of Ophthalmology.
Top Research in Optic Nerve & Disc
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Discussion
Comments and discussion will appear here in a future update.