Glaucoma Journal Club

In this database

39

2015 – 2026

DB Citations

769

across indexed articles

h-index

Not available

Total Citations

Not available

39 articles in Glaucoma Journal Club

Laser Peripheral Iridotomy in Primary Angle Closure: A Report by the American Academy of Ophthalmology.

Laser peripheral iridotomy increases angle width in all stages of primary angle closure and has a good safety profile.

Ophthalmology2018 Jul112 citations
iop-medical-therapyoct-imaging

Long-term Visual Outcomes and Complications of Boston Keratoprosthesis Type II Implantation.

The Boston keratoprosthesis type II is a viable option to salvage vision in patients with poor prognosis for other corneal procedures.

Ophthalmology2017 Jan89 citations
glaucoma-progression

Spectral-Domain OCT: Helping the Clinician Diagnose Glaucoma: A Report by the American Academy of Ophthalmology.

Structural glaucomatous damage can be detected by SD OCT. Optic nerve, RNFL, and macular parameters can help the clinician distinguish the anatomic changes that are associated with patients with glaucoma when compared with normal subjects.

Ophthalmology2018 Nov85 citations
optic-nerveoct-imaging

OCT Angiography for the Diagnosis of Glaucoma: A Report by the American Academy of Ophthalmology.

Vessel density loss associated with glaucoma can be detected by OCTA. Peripapillary, macular, and choroidal vessel density parameters may complement visual field and structural OCT measurements in the diagnosis of glaucoma.

Ophthalmology2021 Aug77 citations
oct-imagingglaucoma-progression

The Effect of Anti-Vascular Endothelial Growth Factor Agents on Intraocular Pressure and Glaucoma: A Report by the American Academy of Ophthalmology.

Intravitreal injection of anti-VEGF agents results in an immediate and transient increase in IOP.

Ophthalmology2019 Apr77 citations
iop-medical-therapyglaucoma-progression

Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Retinal Nerve Fiber Layer Volume.

Compared to 2D RNFL scans, 3D RNFL volume scans less often require manual correction to obtain accurate measurements.

Translational vision science & technology2020 Feb 1242 citations
optic-nerveoct-imaging

Effects of Age, Race, and Ethnicity on the Optic Nerve and Peripapillary Region Using Spectral-Domain OCT 3D Volume Scans.

All of the parameters exhibited age-related declines. RNFL, MDB thickness, and MDB area demonstrated racial and ethnic variations, while peripapillary RT and RV did not.

Translational vision science & technology2018 Nov41 citations
optic-nerveoct-imaging

Swept-Source OCT for Evaluating the Lamina Cribrosa: A Report by the American Academy of Ophthalmology.

Imaging of the lamina cribrosa using SS-OCT has demonstrated that the lamina cribrosa is likely biomechanically active and that significant changes occur in glaucoma.

Ophthalmology2019 Sep37 citations
optic-nerveoct-imaging

Corneal Hysteresis for the Diagnosis of Glaucoma and Assessment of Progression Risk: A Report by the American Academy of Ophthalmology.

Corneal hysteresis is lower in glaucoma patients compared with normal subjects, and lower CH is associated with an increased risk of disease progression.

Ophthalmology2023 Apr29 citations
iop-medical-therapyglaucoma-diagnosis

Enhanced Diagnostic Capability for Glaucoma of 3-Dimensional Versus 2-Dimensional Neuroretinal Rim Parameters Using Spectral Domain Optical Coherence Tomography.

3D neuroretinal rim parameters (MDB, BMO-MRW, and rim volume) demonstrated better diagnostic capability for primary and secondary open-angle glaucomas compared with 2D neuroretinal parameters (rim area, rim thickness).

Journal of glaucoma2017 May29 citations
optic-nerveoct-imaging

Diagnostic Capability of Three-Dimensional Macular Parameters for Glaucoma Using Optical Coherence Tomography Volume Scans.

The diagnostic performance of best macular parameters (GCC-volume-34 and GCC-thickness-34) were similar to or better than 2D RNFL thickness. Manual correction of artifacts with data interpolation is unnecessary in the clinical setting.

Investigative ophthalmology & visual science2018 Oct 118 citations
optic-nerveoct-imaging

Diagnostic Capability of Peripapillary Three-dimensional Retinal Nerve Fiber Layer Volume for Glaucoma Using Optical Coherence Tomography Volume Scans.

Peripapillary 3D RNFL volume showed excellent diagnostic performance for detecting glaucoma.

American journal of ophthalmology2017 Oct18 citations
glaucoma-diagnosisoptic-nerve

Differential Efficacy of Combined Phacoemulsification and Endocyclophotocoagulation in Open-angle Glaucoma Versus Angle-closure Glaucoma.

Eyes with CACG were more responsive to phaco/ECP in terms of IOP and medication reduction compared with eyes with primary open-angle glaucoma.

Journal of glaucoma2019 May16 citations
iop-medical-therapyglaucoma-surgery

Diagnostic Capability of Peripapillary Retinal Volume Measurements in Glaucoma.

Peripapillary RV measurements have excellent ability for diagnosing not only glaucoma patients but also a subset of early glaucoma patients.

Journal of glaucoma2017 Jun14 citations
optic-nerveoct-imaging

Restoration of Vision in Severe, Cicatricial, Ocular Surface Disease With the Boston Keratoprosthesis Type II.

Advances in device design and postoperative care have made implantation of BK2 a viable option for corneal blindness in the setting of severe cicatricial OSD.

American journal of ophthalmology2022 Nov13 citations
glaucoma-progression

Three-Dimensional Optical Coherence Tomography Imaging For Glaucoma Associated With Boston Keratoprosthesis Type I and II.

Spectral domain OCT volume scans offer the possibility to enhance the evaluation of KPro patients with glaucoma by using both 2D and 3D diagnostic parameters that are easily obtained in a clinic setting.

Journal of glaucoma2019 Aug13 citations
optic-nerveoct-imaging

Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography.

Compared to the most commonly used RNFL thickness scans, optic nerve volume scans less frequently require manual correction or repeat scanning to obtain accurate measurements.

Translational vision science & technology2020 Sep12 citations
optic-nerveoct-imaging

Earlier Detection of Glaucoma Progression Using High-Density 3-Dimensional Spectral-Domain OCT Optic Nerve Volume Scans.

High-density 3D SD OCT neuroretinal rim measurements detected glaucoma progression approximately 1 to 2 years earlier compared with current clinically available structural tests (i.e., DP and 2D RNFL thickness measurements).

Ophthalmology. Glaucoma202110 citations
optic-nerveglaucoma-progression

A Patient With Glaucoma With Corneal Edema.

JAMA ophthalmology2020 Aug 19 citations

Endoscopic Cyclophotocoagulation for the Treatment of Glaucoma in Boston Keratoprosthesis Type II Patient.

We describe the surgical technique of endoscopic cyclophotocoagulation in a Boston keratoprosthesis type II patient. This patient with ocular cicatricial pemphigoid had pars plana endoscopic cyclophotocoagula through wounds created in the eyelids.

Journal of glaucoma2017 Apr7 citations
glaucoma-surgery

Three-dimensional Neuroretinal Rim Thickness and Visual Fields in Glaucoma: A Broken-stick Model.

When neuroretinal rim tissue, characterized by MDB thickness in OCT, is below a third of the normal value, VF damage in the decibel scale becomes detectable.

Journal of glaucoma2020 Oct6 citations
optic-nerveoct-imaging

Diagnostic Capability of 3D Peripapillary Retinal Volume for Glaucoma Using Optical Coherence Tomography Customized Software.

The diagnostic capability of RV is similar to RNFL thickness for perimetric open-angle glaucoma, but RV had fewer artifacts compared with RNFL thickness.

Journal of glaucoma2019 Aug4 citations
oct-imagingoptic-nerve

Frequency of Agreement Between Structural and Functional Glaucoma Testing: A Longitudinal Study of 3D OCT and Current Clinical Tests.

Clinical tests of structure and function do not usually progress at the same clinic visit. Most of the time, glaucoma progression is only detected by one or two tests.

American journal of ophthalmology2024 Oct3 citations
visual-fieldglaucoma-progression

Disc Hemorrhages Are Associated With Localized Three-Dimensional Neuroretinal Rim Thickness Progression in Open-Angle Glaucoma.

Glaucoma progression detected by high-density 3D SD-OCT neuroretinal rim measurements preceded DH occurrence in the majority of patients.

American journal of ophthalmology2022 Feb3 citations
optic-nerveglaucoma-progression

Structure-Function Mapping Using a Three-Dimensional Neuroretinal Rim Parameter Derived From Spectral Domain Optical Coherence Tomography Volume Scans.

Three-dimensional MDB neuroretinal rim thickness relates to visual function as strongly as the most commonly used SD-OCT parameter for glaucoma, two-dimensional peripapillary RNFL thickness.

Translational vision science & technology2021 May 32 citations
visual-fieldoptic-nerve

Clinicians' Use of Quantitative Information When Assessing the Rate of Structural Progression in Glaucoma.

The rate of change of RNFLT in the most rapidly changing sector predicted experts' assessment of the rate of structural progression better than global rates or MRW.

Ophthalmology. Glaucoma20221 citations
glaucoma-progressionoptic-nerve

Clinicians' Use of Quantitative Information while Assessing the Rate of Functional Progression in Glaucoma.

Expert academic glaucoma specialists' assessment of the rate of change correlated best with VFI rates, except in eyes with a VFI near the ceiling of 100%.

Ophthalmology. Glaucoma20221 citations
glaucoma-progressionvisual-field

Repair of Tube Erosion by Modifying the Tube Extender.

The modification of the tube extender makes the commercially available tube extender more compact and is useful in cases where conjunctival mobility and space are limited.

Journal of glaucoma2020 Jul1 citations

Corneal Endothelial Keratoplasty Following Glaucoma Treatment: An American Academy of Ophthalmology IRIS® Registry (Intelligent Research in Sight) Analysis.

This large study highlights the substantially elevated risk of endothelial keratoplasty following traditional glaucoma surgeries such as tube/shunt implantation and trabeculectomy as well as the modestly increased risk associated with chronic topical glaucoma therapy.

Ophthalmology. Glaucoma2026 Feb 24
iop-medical-therapyglaucoma-surgery

Comparison of Event-based Analysis Versus Trend-based Analysis in the Detection of Glaucoma Progression by Optical Coherence Tomography 3-Dimensional Rim Measurements.

Compared with trend-based analysis, event-based analysis detected OCT structural progression in more glaucoma patients and at an earlier time point.

Journal of glaucoma2025 Aug 1
glaucoma-progressionvisual-field

In Reply: Protocol For Titrated Endocycloplasty When Combined With Phacoemulsification in an Exclusive Cohort of Angle Closure Glaucoma.

Journal of glaucoma2019 Dec
angle-anatomy

Comprehensive Three-Dimensional Analysis of the Neuroretinal Rim in Glaucoma Using High-Density Spectral-Domain Optical Coherence Tomography Volume Scans.

The 3D MDB thickness had a high diagnostic capability for glaucoma and may be of significant clinical utility.

Investigative ophthalmology & visual science2016 Oct 1
optic-nerveoct-imaging

Patterns of Retinal Nerve Fiber Layer Loss in Different Subtypes of Open Angle Glaucoma Using Spectral Domain Optical Coherence Tomography.

This study suggests that SD-OCT may be able to detect significant differences in patterns of RNFL thinning for different subtypes of OAG.

Journal of glaucoma2016 Oct
oct-imagingoptic-nerve

Diagnostic Performance of a Novel Three-Dimensional Neuroretinal Rim Parameter for Glaucoma Using High-Density Volume Scans.

Compared with the 2D RNFL thickness parameter, the 3D MDB neuroretinal rim thickness parameter had uniformly equal or better diagnostic performance for glaucoma in all regions and was significantly better in the nasal region.

American journal of ophthalmology2016 Sep
optic-nerveoct-imaging

New Ultrasound Biomicroscopy Iris Findings in Juvenile Xanthogranuloma.

Untreated, iris juvenile xanthogranuloma may lead to corneal blood staining, glaucoma, and amblyopia. An understanding of the full range of ultrasound features of juvenile xanthogranuloma expands our appreciation for the clinical findings in this condition.

Journal of glaucoma2016 Aug
iop-medical-therapy

Facilitating Glaucoma Diagnosis With Intereye Retinal Nerve Fiber Layer Asymmetry Using Spectral-Domain Optical Coherence Tomography.

Intereye RNFL asymmetry may be a useful clinical OCT measurement to provide quantitative assessment of early glaucomatous damage. Newly developed algorithms for intereye RNFL asymmetry may improve the ability to detect glaucoma.

Journal of glaucoma2016 Feb
glaucoma-diagnosisoptic-nerve

The Effect of Phacoemulsification on Intraocular Pressure in Glaucoma Patients: A Report by the American Academy of Ophthalmology.

Phacoemulsification typically results in small, moderate, and marked reductions of IOP and medications for patients with POAG, PXG, and PACG, respectively, and using 1 to 2 medications before surgery.

Ophthalmology2015 Jul
iop-medical-therapyglaucoma-surgery

Diagnostic capability of peripapillary retinal thickness in glaucoma using 3D volume scans.

Peripapillary RT measurements from 3D volume scans showed excellent diagnostic performance for detecting both glaucoma and early glaucoma patients.

American journal of ophthalmology2015 Mar
optic-nerveoct-imaging

Patient characteristics associated with artifacts in Spectralis optical coherence tomography imaging of the retinal nerve fiber layer in glaucoma.

Clinicians should first assess scans for artifacts before making therapeutic decisions based on RNFL thickness measurements.

American journal of ophthalmology2015 Mar
optic-nerveoct-imaging