Diagnostic Capability of 3D Peripapillary Retinal Volume for Glaucoma Using Optical Coherence Tomography Customized Software.
Yingna Liu, Firas Jassim, Boy Braaf, Ziad Khoueir, Linda Yi-Chieh Poon, Geulah S Ben-David, Georgia Papadogeorgou, Edem Tsikata, Huseyin Simavli, Christian Que, Ramon Lee, Eric Shieh, Benjamin J Vakoc, Brett E Bouma, Boer Johannes F de, Teresa C Chen
Summary
The diagnostic capability of RV is similar to RNFL thickness for perimetric open-angle glaucoma, but RV had fewer artifacts compared with RNFL thickness.
Abstract
UNLABELLED
PRéCIS:: The diagnostic capability of peripapillary retinal volume is similar to peripapillary retinal nerve fiber layer thickness for diagnosing glaucoma, but with fewer artifacts.
PURPOSE
To compare the diagnostic capability of 3-dimensional peripapillary retinal volume (RV) versus 2-dimensional peripapillary retinal nerve fiber layer (RNFL) thickness for open-angle glaucoma.
PATIENTS AND METHODS
A retrospective cross-sectional analysis was conducted. A total of 180 subjects (113 open-angle glaucoma, 67 normal participants) had spectral domain optical coherence tomography volume scans and RNFL thickness measurements. Peripapillary RV values were calculated using a custom-designed program with 4 circumpapillary annuli (CA): CA1 had circle diameters of 2.5 and 3.5 mm; CA2, 3 and 4 mm; CA3, 3.5 and 4.5 mm; and CA4, 4 and 5 mm. Area under the receiver operating characteristic curves were calculated for global, quadrant, and octant regions for RV (CA1 to CA4) and RNFL thickness. Pair-wise comparisons were conducted. Artifacts rates were determined.
RESULTS
Mean age was 62.7±15.4 years, and 47.8% (86/180) were male. Among RV measurements, best diagnostic performances were for the smallest 2 annuli for inferior RV (CA1: 0.964, CA2: 0.955). Of the 4 annuli, CA1 had the highest diagnostic performance. Of specific regions, the inferior RV quadrant had the highest performance across CA1 to CA4. Peripapillary RV had similar diagnostic capability compared with RNFL thickness (P>0.05). The artifact rate per B-scan for RV was 6.0%, which was significantly lower compared with 2-dimensional RNFL thickness in the same patient population (32.2%, P<0.0001).
CONCLUSIONS
The diagnostic capability of RV is similar to RNFL thickness for perimetric open-angle glaucoma, but RV had fewer artifacts compared with RNFL thickness.
More by Yingna Liu
View full profile →The Effect of Tube Location on Corneal Endothelial Cells in Patients with Ahmed Glaucoma Valve.
Diagnostic Capability of Peripapillary Three-dimensional Retinal Nerve Fiber Layer Volume for Glaucoma Using Optical Coherence Tomography Volume Scans.
Diagnostic Capability of Peripapillary Retinal Volume Measurements in Glaucoma.
Top Research in OCT & Imaging
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Deep learning in ophthalmology: The technical and clinical considerations.
Anterior segment optical coherence tomography.
Discussion
Comments and discussion will appear here in a future update.