Integrating opportunistic glaucoma screening into general health examinations in China: A pilot study.
Shaodan Zhang, Jing Sun, Shanshan Liu, Yuanbo Liang, Ying Hu, Nathan Congdon, Chi Pui Pang, Hailin Wang
Summary
This novel screening model provides opportunities to improve glaucoma detection at low cost. Interventions to improve follow-up are needed.
Abstract
IMPORTANCE
Under-detection and late diagnosis are major causes of glaucoma-related visual impairment. Cost-effective opportunistic glaucoma screening is of great interest in the early identification and prevention of glaucoma.
BACKGROUND
To describe the results of a health examination centre-based opportunistic glaucoma screening and referral model.
DESIGN
This single centre cross-sectional study was conducted in a health examination centre affiliated to a tertiary hospital in Shenyang, northeastern China.
PARTICIPANTS
From 21 March to 30 September 2016, 14 367 individuals aged ≥ 30 years undergoing routine physical examinations were invited for this glaucoma screening.
METHODS
Presenting visual acuity, non-contact pneumotonometry and non-mydriatic fundus photography were evaluated. Fundus photographs were classified as non-glaucoma, possible, probable and definitive glaucoma. Participants with probable and definite glaucomatous discs or intraocular pressure ≥ 24 mmHg were referred for definitive examinations.
MAIN OUTCOME MEASURES
Detection rate of glaucoma suspects and ocular hypertension (OHT). Cost to identify a single case with suspected and diagnosed glaucoma was also calculated.
RESULTS
Altogether, 277 glaucoma suspects and 327 ocular hypertension suspects were identified. Among 190 participants with probable/definite glaucomatous discs, 93 (48.9%) accepted further examination. Among these, 78 were diagnosed as glaucoma, seven as suspects and eight were excluded. Only 98 ocular hypertension suspects (30.0%) accepted further examinations: eight had primary angle closure and 23 had confirmed ocular hypertension. The cost to identify a single glaucoma suspect and definite glaucoma case were US$135 and US$857, respectively.
CONCLUSIONS AND RELEVANCE
This novel screening model provides opportunities to improve glaucoma detection at low cost. Interventions to improve follow-up are needed.
Keywords
More by Shaodan Zhang
View full profile →Parapapillary Choroidal Microvasculature Dropout Is Associated With the Decrease in Retinal Nerve Fiber Layer Thickness: A Prospective Study.
Efficacy of bleb-independent penetrating canaloplasty in primary angle-closure glaucoma: one-year results.
Achieving Inner Aqueous Drain in Glaucoma Secondary to Iridocorneal Endothelial Syndrome: One Year Results of Penetrating Canaloplasty.
Top Research in Diagnosis & Screening
Browse all →Efficacy of a Deep Learning System for Detecting Glaucomatous Optic Neuropathy Based on Color Fundus Photographs.
Dry eye disease and oxidative stress.
Central Corneal Thickness in the Ocular Hypertension Treatment Study (OHTS).
Discussion
Comments and discussion will appear here in a future update.