Remote Grading of the Anterior Chamber Angle Using Goniophotographs and Optical Coherence Tomography: Implications for Telemedicine or Virtual Clinics.
Summary
Although moderate agreement between graders and ground truth could be obtained under binary evaluations, angle grades were generally underestimated. Factors affecting concordance were primarily the extremes of the ground truth angle and iris contour.
Abstract
PURPOSE
To evaluate the agreement and accuracy of grading goniophotographs and anterior segment optical coherence tomography (AS-OCT) results for assessment of the anterior chamber angle, and elicit factors driving concordance between perceived grade and ground truth.
METHODS
Three clinicians evaluated the goniophotographs and AS-OCT results of 75 patients. Graders' impressions of the angle grade, trabecular pigmentation, and iris contour were compared with the ground truth gonioscopic examination result when physically performed by a senior optometrist. Percentage agreement and kappa statistics were calculated. Binary logistic regression was used to elicit factors for accurate grading.
RESULTS
Exact angle matches and binary (open or closed) evaluations were above guessing rate for all graders. There was a systematic bias toward underestimating the angle structure across all graders, especially at the superior angle, by approximately 1 ordinal unit. Kappa statistics showed fair-moderate agreement for exact (0.387-0.520) and binary (0.347-0.520) angle evaluations. Agreement was unchanged when using a multimodal approach (0.373-0.523). Factors driving concordance were primarily related to the extremes of the anterior chamber angle configuration (shallow or deep structures, and iris contour). However, prediction models did not fully explain the levels of concordance with the ground truth (maximumamongst models 0.177).
CONCLUSIONS
Although moderate agreement between graders and ground truth could be obtained under binary evaluations, angle grades were generally underestimated. Factors affecting concordance were primarily the extremes of the ground truth angle and iris contour.
TRANSLATIONAL RELEVANCE
We highlight factors affecting accuracy of grading goniophotography and AS-OCT images of the anterior chamber angle.
Keywords
More by Jack Phu
View full profile →Clinical Evaluation of Swedish Interactive Thresholding Algorithm-Faster Compared With Swedish Interactive Thresholding Algorithm-Standard in Normal Subjects, Glaucoma Suspects, and Patients With Glaucoma.
Comparison of 10-2 and 24-2C Test Grids for Identifying Central Visual Field Defects in Glaucoma and Suspect Patients.
Ability of 24-2C and 24-2 Grids to Identify Central Visual Field Defects and Structure-Function Concordance in Glaucoma and Suspects.
Top Research in OCT & Imaging
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Deep learning in ophthalmology: The technical and clinical considerations.
Anterior segment optical coherence tomography.
Discussion
Comments and discussion will appear here in a future update.