Outflow Facility Effects of 3 Schlemm's Canal Microinvasive Glaucoma Surgery Devices.
Summary
The longer the MIGS device, and thus the more SC that it dilates, the greater the outflow facility.
Abstract
PURPOSE
To study the effect of 3 Schlemm's canal (SC) microinvasive glaucoma surgery (MIGS) devices on outflow facility.
DESIGN
Paired comparisons, randomized design, baseline-controlled study.
PARTICIPANTS
Thirty-six pairs of dissected anterior segments from donated human eye bank eyes without glaucoma were studied. A baseline measurement was collected from each eye to serve as its control.
METHODS
Using a constant pressure perfusion method, outflow facility was measured in paired eyes from human donors. Measurements were made at perfusion pressures of 10 mmHg, 20 mmHg, 30 mmHg, and 40 mmHg. Outflow facility was measured before (baseline control) and after the implantation of an SC glaucoma drainage device or sham procedure. Three sets of experiments were carried out comparing 1 and 2 iStent Trabecular Micro-Bypass Stents and 2 iStent Inject implants with the Hydrus Microstent.
MAIN OUTCOME MEASURES
Change in outflow facility from baseline or contralateral eye.
RESULTS
After Hydrus placement, the outflow facility increased from 0.23±0.03 μl/minute per millimeter of mercury at baseline to 0.38±0.03 μl/minute per millimeter of mercury (P < 0.001). The percent increase in outflow facility was 79±21% for the Hydrus and 11±16% for the 2 iStent Inject devices, a difference that was significant (P = 0.018). Outflow facility with 1 iStent (0.38±0.07 μl/minute per millimeter of mercury) was greater than baseline (0.28±0.03 μl/minute per millimeter of mercury; P = 0.031). The 1 iStent showed a greater increase in outflow facility from baseline (0.10±0.04 μl/minute per millimeter of mercury) compared with the sham procedure (-0.08±0.05 μl/minute per millimeter of mercury; P = 0.042). No other significant differences were found.
CONCLUSIONS
The longer the MIGS device, and thus the more SC that it dilates, the greater the outflow facility.
More by Carol B Toris
View full profile →Mechanism of Action of Selective Laser Trabeculoplasty and Predictors of Response.
Consensus Recommendation for Mouse Models of Ocular Hypertension to Study Aqueous Humor Outflow and Its Mechanisms.
NCX 667, a Novel Nitric Oxide Donor, Lowers Intraocular Pressure in Rabbits, Dogs, and Non-Human Primates and Enhances TGFβ2-Induced Outflow in HTM/HSC Constructs.
Top Research in Glaucoma Surgery
Browse all →Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
Efficacy, Safety, and Risk Factors for Failure of Standalone Ab Interno Gelatin Microstent Implantation versus Standalone Trabeculectomy.
Prospective, Randomized, Controlled Pivotal Trial of an Ab Interno Implanted Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract: Two-Year Results.
Discussion
Comments and discussion will appear here in a future update.