Clinical Outcomes After Ahmed Glaucoma Valve Implantation for Pediatric Glaucoma After Congenital Cataract Surgery.
Summary
Despite a decrease in surgical success over time, AGV implantation was successfully used for IOP control in the majority of our pediatric eyes with glaucoma after congenital cataract surgery.
Abstract
PRCIS
Ahmed valve success for glaucoma following congenital cataract surgery lasts at least 5 years in most eyes, and >10 years in some cases. The procedure is a valuable option for these patients.
PURPOSE
The aim of the study was to report on the results of Ahmed valve implantation in children with glaucoma following congenital cataract surgery.
PATIENTS AND METHODS
Medical records were reviewed for 41 pediatric eyes (27 patients) with glaucoma after congenital cataract surgery with Ahmed glaucoma valve (AGV) implantation between 2007 and 2018. The primary outcome measure was surgical success, defined as intraocular pressure (IOP) ≤22 mm Hg (with or without glaucoma medications) on 2 consecutive follow-up visits, without glaucoma reoperation, and without significant visual complications during the follow-up period.
RESULTS
Median age at the time of AGV implantation was 80 months (range: 14 to 146 mo) and the mean follow-up period was 61.1±46.5 months. The cumulative probability of surgical success was 95.1%, 89.8%, 83.1%, and 72.6% at 12, 24, 60, and 84 months, respectively. IOP significantly decreased from 35.8±7.4 mm Hg before valve implantation to 18.7±6.5 mm Hg at the last recorded visit (51.4% decrease; P<0.0001). Most eyes (79%) required medications for pressure control. Complications occurred in 14 eyes (34%), with 12 of these remaining successful. Early hypotony was the most common complication (19.5%). Retinal detachment occurred in 1 eye.
CONCLUSIONS
Despite a decrease in surgical success over time, AGV implantation was successfully used for IOP control in the majority of our pediatric eyes with glaucoma after congenital cataract surgery. Most complications were managed effectively and surgical success was maintained.
More by Orna Geyer
View full profile →Ex-PRESS Miniature Glaucoma Shunt Versus Ahmed Glaucoma Valve in the Surgical Treatment of Glaucoma in Pseudophakic Patients.
The Impact of Femtosecond Laser on Intraocular Pressure With Cataract Surgery in Healthy Eyes.
Use of Autologous Scleral Graft in Ahmed Glaucoma Valve Surgery.
Top Research in IOP & Medical Therapy
Browse all →The Complications of Myopia: A Review and Meta-Analysis.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
In the Knowledge Library
Discussion
Comments and discussion will appear here in a future update.