Endothelial Cell Density After XEN Implant Surgery: Short-term Data From the Italian XEN Glaucoma Treatment Registry (XEN-GTR).
Francesco Oddone, Gloria Roberti, Chiara Posarelli, Luca Agnifili, Leonardo Mastropasqua, Carmela Carnevale, Ferrari Tommaso Micelli, Vincenzo Pace, Matteo Sacchi, Elena Cremonesi, Maurizio Uva, Martina Menchini, Lorenza Brescia, Michele Figus
Summary
The mean ECD reduction 6 months after XEN implantation was low. The ECD reduction in the XEN+phaco group was larger than in the XEN-solo group but was similar to that observed in the phaco-solo group.
Abstract
PRECIS
XEN implant was associated with low endothelial cell density (ECD) reduction. In fact, when combined with phacoemulsification, the reduction in ECD was similar to that expected after phacoemulsification alone.
PURPOSE
The purpose of this study was to assess the impact of XEN implant, either alone or in combination with phacoemulsification, on ECD.
METHODS
Multicenter, prospective, observational study conducted on consecutive open-angle glaucoma patients, who were enrolled in the Italian XEN Glaucoma Treatment Registry and have complete endothelial cell count data at baseline and at 6 months after implantation. The primary endpoint was the mean percentage change in ECD between baseline and month 6.
RESULTS
The study included 108 open-angle glaucoma eyes (68 in the XEN-solo and 40 eyes in the XEN+phaco groups) and 60 control eyes (phaco-solo group). As compared with baseline, mean (95% confidence interval, CI) ECD reduction was -5.6% (-7.0% to -4.9%), -11.3% (-13.8% to -10.9%), and -13.0% (14.8% to -11.8%) in the XEN-solo, XEN+phaco, and phaco-solo groups, respectively (P=0.0004, <0.0001, and <0.0001, respectively). As compared with the XEN-solo group, the ECD reduction was significantly greater in the XEN+phaco group (mean difference=5.7%; 95%
CI
4.1%-7.3%, P<0.0001) and in the phaco-solo group (mean difference=7.4%; 95%
CI
5.7%-9.1%, P<0.0001). ECD reduction was similar in XEN+phaco and phaco-solo groups (P=0.9). In absolute terms, ECD reduction was significantly greater in the XEN+phaco (mean difference=169±306, P=0.021) and in the phaco-solo (mean difference=192±302, P=0.0022) groups than in the XEN-solo group.
CONCLUSIONS
The mean ECD reduction 6 months after XEN implantation was low. The ECD reduction in the XEN+phaco group was larger than in the XEN-solo group but was similar to that observed in the phaco-solo group.
More by Francesco Oddone
View full profile →European study of the efficacy of a cross-linked gel stent for the treatment of glaucoma.
A Comparison between the Compass Fundus Perimeter and the Humphrey Field Analyzer.
In Vivo Distribution of Corneal Epithelial Dendritic Cells in Patients With Glaucoma.
Top Research in Glaucoma Surgery
Browse all →Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
Efficacy, Safety, and Risk Factors for Failure of Standalone Ab Interno Gelatin Microstent Implantation versus Standalone Trabeculectomy.
Prospective, Randomized, Controlled Pivotal Trial of an Ab Interno Implanted Trabecular Micro-Bypass in Primary Open-Angle Glaucoma and Cataract: Two-Year Results.
Discussion
Comments and discussion will appear here in a future update.