Multimodal Machine Learning Using Visual Fields and Peripapillary Circular OCT Scans in Detection of Glaucomatous Optic Neuropathy.
Jian Xiong, Fei Li, Diping Song, Guangxian Tang, Junjun He, Kai Gao, Hengli Zhang, Weijing Cheng, Yunhe Song, Fengbin Lin, Kun Hu, Peiyuan Wang, Li Ji-Peng Olivia, Tin Aung, Yu Qiao, Xiulan Zhang, Daniel Ting
Summary
FusionNet, developed using paired VF and OCT data, demonstrated superior performance to both VFNet and OCTNet in detecting GON, suggesting that multimodal machine learning models are valuable in detecting GON.
Abstract
PURPOSE
To develop and validate a multimodal artificial intelligence algorithm, FusionNet, using the pattern deviation probability plots from visual field (VF) reports and circular peripapillary OCT scans to detect glaucomatous optic neuropathy (GON).
DESIGN
Cross-sectional study.
SUBJECTS
Two thousand four hundred sixty-three pairs of VF and OCT images from 1083 patients.
METHODS
FusionNet based on bimodal input of VF and OCT paired data was developed to detect GON. Visual field data were collected using the Humphrey Field Analyzer (HFA). OCT images were collected from 3 types of devices (DRI-OCT, Cirrus OCT, and Spectralis). Two thousand four hundred sixty-three pairs of VF and OCT images were divided into 4 datasets: 1567 for training (HFA and DRI-OCT), 441 for primary validation (HFA and DRI-OCT), 255 for the internal test (HFA and Cirrus OCT), and 200 for the external test set (HFA and Spectralis). GON was defined as retinal nerve fiber layer thinning with corresponding VF defects.
MAIN OUTCOME MEASURES
Diagnostic performance of FusionNet compared with that of VFNet (with VF data as input) and OCTNet (with OCT data as input).
RESULTS
FusionNet achieved an area under the receiver operating characteristic curve (AUC) of 0.950 (0.931-0.968) and outperformed VFNet (AUC, 0.868 [95% confidence interval (CI), 0.834-0.902]), OCTNet (AUC, 0.809 [95% CI, 0.768-0.850]), and 2 glaucoma specialists (glaucoma specialist 1: AUC, 0.882 [95% CI, 0.847-0.917]; glaucoma specialist 2: AUC, 0.883 [95% CI, 0.849-0.918]) in the primary validation set. In the internal and external test sets, the performances of FusionNet were also superior to VFNet and OCTNet (FusionNet vs VFNet vs OCTNet: internal test set 0.917 vs 0.854 vs 0.811; external test set 0.873 vs 0.772 vs 0.785). No significant difference was found between the 2 glaucoma specialists and FusionNet in the internal and external test sets, except for glaucoma specialist 2 (AUC, 0.858 [95% CI, 0.805-0.912]) in the internal test set.
CONCLUSIONS
FusionNet, developed using paired VF and OCT data, demonstrated superior performance to both VFNet and OCTNet in detecting GON, suggesting that multimodal machine learning models are valuable in detecting GON.
Keywords
More by Jian Xiong
View full profile →Digital Gonioscopy Based on Three-dimensional Anterior-Segment OCT: An International Multicenter Study.
A Retrospective Comparison of Deep Learning to Manual Annotations for Optic Disc and Optic Cup Segmentation in Fundus Photographs.
Assessment of Artifacts in Swept-Source Optical Coherence Tomography Angiography for Glaucomatous and Normal Eyes.
Top Research in Visual Field
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Relationship between Optical Coherence Tomography Angiography Vessel Density and Severity of Visual Field Loss in Glaucoma.
Improving our understanding, and detection, of glaucomatous damage: An approach based upon optical coherence tomography (OCT).
Discussion
Comments and discussion will appear here in a future update.