Changes in Iris Stiffness and Permeability in Primary Angle Closure Glaucoma.
Satish K Panda, Royston K Y Tan, Tin A Tun, Martin L Buist, Monisha Nongpiur, Mani Baskaran, Tin Aung, Michaël J A Girard
Summary
This study suggests that the biomechanical properties of the iris in PACG are different from those in healthy controls.
Abstract
PURPOSE
To evaluate the biomechanical properties of the iris by evaluating iris movement during pupil constriction and to compare such properties between healthy and primary angle-closure glaucoma (PACG) subjects.
METHODS
A total of 140 subjects were recruited for this study. In a dark room, the anterior segments of one eye per subject were scanned using anterior segment optical coherence tomography imaging during induced pupil constriction with an external white light source of 1700 lux. Using a custom segmentation code, we automatically isolated the iris segments from the AS-OCT images, which were then discretized and transformed into a three-dimensional point cloud. For each iris, a finite element (FE) mesh was constructed from the point cloud, and an inverse FE simulation was performed to match the clinically observed iris constriction in the AS-OCT images. Through this optimization process, we were able to identify the elastic modulus and permeability of each iris.
RESULTS
For all 140 subjects (95 healthy and 45 PACG of Indian/Chinese ethnicity; age 60.2 ± 8.7 for PACG subjects and 57.7 ± 10.1 for healthy subjects), the simulated deformation pattern of the iris during pupil constriction matched well with OCT images. We found that the iris stiffness was higher in PACG than in healthy controls (24.5 ± 8.4 kPa vs. 17.1 ± 6.6 kPa with 40 kPa of active stress specified in the sphincter region; P < 0.001), whereas iris permeability was lower (0.41 ± 0.2 mm2/kPa s vs. 0.55 ± 0.2 mm2/kPa s; p = 0.142).
CONCLUSIONS
This study suggests that the biomechanical properties of the iris in PACG are different from those in healthy controls. An improved understanding of the biomechanical behavior of the iris may have implications for the understanding and management of angle-closure glaucoma.
More by Satish K Panda
View full profile →Describing the Structural Phenotype of the Glaucomatous Optic Nerve Head Using Artificial Intelligence.
The three-dimensional structural configuration of the central retinal vessel trunk and branches as a glaucoma biomarker.
Differing Associations between Optic Nerve Head Strains and Visual Field Loss in Patients with Normal- and High-Tension Glaucoma.
Top Research in OCT & Imaging
Browse all →Optical coherence tomography angiography: A comprehensive review of current methods and clinical applications.
Deep learning in ophthalmology: The technical and clinical considerations.
Anterior segment optical coherence tomography.
In the Knowledge Library
Discussion
Comments and discussion will appear here in a future update.