Methodological Approach to Improve Surgical Outcomes of a Pig Subretinal Implantation Model.
Fukutaro Mano, Jarel K Gandhi, Silva Raphael Pereira da, Aline Do Amaral Silva, Lucas Iezzi, Raymond Iezzi, Jose S Pulido, Alan D Marmorstein
Summary
For subretinal implantation in pigs, a modified procedure to precauterize the choroid before sclerotomy combined with an instrument that better fills the scleral opening decreases bleeding, hypotony, and open sclerotomy time, improving the success rate.
Abstract
PURPOSE
To improve outcomes for subretinal implantation surgery in pigs.
METHODS
Analysis of variables affecting the success of subretinal implantation surgery was performed on videos of 37 surgeries. Ex vivo experiments were conducted to measure intraocular pressure (IOP) and test various prototyped implanters for effectiveness at maintaining IOP.
RESULTS
A video analysis revealed a prolonged sclerotomy open time owing to a combination of uncontrolled bleeding and excessive fluid outflow often resulting in retinal prolapse. Precauterization of the choroid before full-thickness sclerotomy (n = 10) resulted in a reduced incidence of uncontrolled bleeding from 39.1% (9/23) versus 0% (0/10) (P = 0.005) and improved implantation success from 73% to 90%. An ex vivo analysis of the IOP revealed a mean decrease in the IOP from 30.2 ± 3.0 mm Hg to 5.0 ± 2.1 mm Hg after a fully penetrating sclerotomy. To address this situation, we produced a series of plugs that integrated with a custom implant insertion device to seal the sclerotomy during implantation. The use of the plugs was cumbersome, however, and so we opted instead to increase the width of the inserter tip to fill the open sclerotomy. This improved device restored and maintained IOP during implantation (27.1 ± 1.9 mm Hg). Combined with precauterization the improved inserter resulted in 100% successful implantation (n = 4).
CONCLUSIONS
For subretinal implantation in pigs, a modified procedure to precauterize the choroid before sclerotomy combined with an instrument that better fills the scleral opening decreases bleeding, hypotony, and open sclerotomy time, improving the success rate.
TRANSLATIONAL RELEVANCE
Better management of IOP and bleeding from a sclerotomy will improve implant-based therapies.
Top Research in IOP & Medical Therapy
Browse all →The Complications of Myopia: A Review and Meta-Analysis.
Inflammation in Glaucoma: From the back to the front of the eye, and beyond.
Treatment Outcomes in the Primary Tube Versus Trabeculectomy Study after 1 Year of Follow-up.
In the Knowledge Library
Discussion